Setting method 1: by gyrocompass specifications
1) Gyrocompass type | 2) Frequency |
Gyrocompass | SW | SW | SW | JP1 |
type |
| |||
|
|
|
|
|
AC synchronous | OFF | OFF | OFF | #1, |
|
|
|
| #2, #3 |
|
|
|
|
|
DC synchronous | OFF | OFF | OFF | #2, |
|
|
|
| #3, #4 |
|
|
|
|
|
DC step | ON | OFF | OFF | #4, |
|
|
|
| #5, #6 |
|
|
|
|
|
OFF | ON | OFF | #4, | |
pulsating current |
|
|
| #5, #6 |
|
|
|
|
|
ON | ON | OFF | #4, | |
pulsating current |
|
|
| #5, #6 |
|
|
|
|
|
Frequency | SW | SW | Remarks |
|
| ||
|
|
|
|
50/60 Hz | OFF | OFF | AC synchronous |
|
|
| pulsating current |
|
|
|
|
400 Hz | ON | OFF | AC synchronous |
|
|
| pulsating current |
|
|
|
|
500 Hz | OFF | ON | AC synchronous |
|
|
| pulsating current |
|
|
|
|
DC | ON | ON | DC synchronous |
|
|
| DC step |
|
|
|
|
3)Rotor voltage (between R1 & R2)
Rotor voltage | SW | JP3 | |
|
|
|
|
20 | V to 45 VAC | ON | #2 |
|
|
|
|
30 | V to 70 VAC | OFF | #2 |
|
|
|
|
40 | V to 90 VAC | ON | #1 |
|
|
|
|
60 | V to 135 VAC | OFF | #1 |
|
|
|
|
4)Stator voltage (between S1 and S2)
Stator voltage | SW | SW | JP2 | |||
|
|
|
|
|
| |
20 | V to 45 | VAC, or | ON | OFF | #2 | |
20 | V to 60 | VDC | ||||
|
|
| ||||
|
|
|
|
|
| |
20 | V to 45 | VAC, or | OFF | OFF | #2 | |
20 | V to 60 | VDC | ||||
|
|
| ||||
|
|
|
| |||
40 V to 90 VAC | ON | OFF | #1 | |||
|
|
|
| |||
60 V to 135 VAC | OFF | OFF | #1 | |||
|
|
|
|
|
|
5) Ratio
Ratio | SW | ||
|
|
|
|
360x | OFF | OFF | OFF |
|
|
|
|
180x | ON | OFF | OFF |
|
|
|
|
90X | OFF | ON | OFF |
|
|
|
|
36X | ON | ON | OFF |
|
|
|
|
6) Supply voltage
Supply voltage | JP4 | JP5 | |||
|
|
|
|
| |
20 | V to 45 | VAC, or | #2 | #2 | |
20 | V to 60 | VDC |
|
| |
|
|
|
|
| |
30 | V to 135 | VAC, or | #1 | #1 | |
40 | V to 100 | VDC |
|
| |
|
|
|
|
|
|
7)
Select data transmitting interval for ports 1 to 6 by jumper wires JP6 and JP7.
Note: The Tx interval is available in 25 ms or 200 ms. 25 ms is for radar; 200 ms is for all other equipment.
8)
Tx | |
interval |
|
|
|
2 seconds | ON |
|
|
1 second | OFF |
|
|