Furuno FR-2115/2125 manual Display Unit, Before mounting the display unit, Mounting procedure

Page 13

1.2 Display Unit

Before mounting the display unit

If Gyro Converter GC-8 (option) is to be used, install and setup the GYRO CON- VERTER Board before mounting the display unit, because of the difficulty involved in doing it after the display unit is installed. Instructions for installation and setup are in Chapter 4.

Mounting considerations

When selecting a mounting location, keep in mind the following points:

Select a location where the display unit can be viewed and operated conve- niently and where the screen can be viewed while facing towards the bow.

Locate the unit out of direct sunlight and way from heat sources because of heat that can build up inside the cabinet.

Locate the equipment away from places subject to water splash and rain.

The display unit is very heavy. Be sure the mounting location is strong enough to support the weight of the unit under the continued vibration which is normally experienced on the ship. If necessary reinforce the mounting location.

Determine the mounting location considering the length of the signal cable be- tween the scanner unit and the display unit. (The signal cable comes in lengths of 15, 20 or 30 meters; maximum 100 meters).

Leave sufficient space on the sides and rear of the unit to facilitate mainte- nance. Also, leave a foot or so of “service loop” in cables behind the unit so it can be pulled forward for servicing or easy removal of connectors.

A magnetic compass will be affected if placed too close to the display unit. Observe the following compass safe distances to prevent deviation of a mag- netic compass: Standard compass, 1.70 m, Steering compass, 0.90 m.

Mounting procedure

Tabletop mounting

Two people are necessary to complete this procedure.

1.Make four holes of 12 mm di- ameter in the mounting location referring to the outline drawing at end of this manual.

2.Unfasten the screws fixing the right and left arm covers on the control head.

3.Unfasten bolts (four total) hid- den by the arm covers.

Left and right arm covers

M4X10

Figure 1-6 Control head

1-5

Image 13
Contents Marine Radar B . N o . I M E 3 4 6 4 0 M Safety Instructions Power Switch Power Switch in AC Powered Display UnitTable of Contents Standard Supply Equipment ListsName Type Code No Qty Remarks Optional EquipmentSystem Configuration Mounting considerations Scanner UnitAssembling the scanner unit Be sure to remove the guide pinsFastening the radiator to the radiator bracket Fastening the scanner unit to the mounting platformScanner unit, front view Display Unit Mounting procedureBefore mounting the display unit Tabletop mountingStay Setting catch to hole in stay Console type mounting 11 How to dismount the PTU coverSeparating the control head Display unit modification procedureSeparate type control head kit Type OP03-151, No 13 Detaching the control head Control head modification procedureConnection of display unit to control head PlateAttachment of hood 15 How to attach KB fixing plateWiring Scanner unit, front view, cover removed Correct seating of waterproofing gasket Fabricating signal cable S03-75 =EMI cores Outer cores RFC-13 thick Inner cores RFC-10 thin Fabricating signal cable S03-74DPYCY-3.5 Fabricating the AC power cable suppliedCVV-S 82C Fabricating the DC power cable CVV-S 8 x 2C, optionLeading in cables to the display unit Cable fed from rear of display unit DefaultCables fed from bottom of display unit for console mount Cable fed from outside display unitM4X8 2 pcs ConnectionsConnectors on the INT Board Connectors on the INT BoardHow to attach NH connector Changing AC Power SpecificationAccessing Menus for Initialization and Adjustment Tuning InitializationAdjusting Video Signal Level Restoring default settingsPicture appears Deviated counterclockwise Heading AlignmentSuppressing Main Bang Adjusting Sweep TimingMagnetron heater voltage rating Confirming Magnetron Heater VoltagePress Radar Menu 0 0 0 Initial Setting MenusInitial SETTING2 menu Initial SETTING1 menuInitial SETTING3 menu OWN Ship Information menu Initial SETTING4 menuGyro Converter GC-8 Installation and connection of the Gyro Converter BoardGyro Converter Board 64P1106 DIP switch, jumper wire settings Connection of external power supplyDefault setting Gyrocompass type Frequency Setting method 1 by gyrocompass specificationsJP1 JP2 JP3 JP4 JP5 Setting method 2 by make and model of gyrocompassSW1 Setting the heading readout on the radar displayARP Board ARP-26 Installation of the ARP boardARP Board 18P9002B ARP board adjustmentARP Board ARP-26 Final checkTable top/console type RP Board RP-2610 Display pedestal Necessary parts RP-26-Z-2E Code no Separate type control head13 Display pedestal, front view Necessary parts PM-30 and OP03-150 Code no Performance Monitor PM-30Procedure Alarm KitNecessary parts OP03-156 Code no 16 Display unit, inside view AC-DC Conversion Kit Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page