Furuno FR-2115/2125 manual Initial Setting Menus, Press Radar Menu 0 0 0

Page 37

3.8 Initial Setting Menus

The INITIAL SETTING menus (four menus) and the OWN SHIP INFORMATION menu setup the radar according to expected usage, authorities specification, ship's characteristics, operator's preference, etc. Set items on each menu in accor- dance with regulations/operator's preference. After entering initial settings, reset the power.

Press [RADAR MENU] [0] [0] [0] [2]

[OWN SHIP INFORMATION]

 

 

 

1 [INITIAL SETTING(1)]

 

 

 

 

2 SHIP’S LENGTH

000m

 

 

 

3 SHIP’S WIDTH

00m

 

 

 

4 RADAR POSN

FOR BOW 000m

 

 

 

FOR PORT

00m

 

 

5 NAV ANT POSN

FOR BOW 000m

 

 

 

FOR PORT

00m

 

 

 

 

 

6 TURN RATE

00KT

 

 

Press [6]

 

00.0° / s

 

 

 

 

00KT

 

 

 

 

00.0° / s

 

 

 

7 SPEED RATE

00KT

 

 

 

 

0.00KT/s

 

 

 

 

00KT

 

 

 

 

0.00KT/s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press [0]

 

 

 

 

 

 

 

 

 

 

 

[INITIAL SETTING 4]

 

 

1 [INITIAL SETTING(3)]

 

 

 

 

2 MODEL

 

FR-2115, 2125/

 

 

 

 

OTHER X-BND/

 

 

 

 

FR-2165DS, 2135SW/

 

 

 

 

OTHER S-BND

 

 

3 TYPE

 

R/N/G/W

 

 

4 CTR STC CURVE

 

L/M/H

 

 

5 RJ-7

 

OFF/ON

 

 

6 RJ-8

 

OFF/ON

 

 

 

ANT A

 

 

 

 

FR-2115, 2125/

 

 

 

 

OTHER X-BND/

 

 

 

 

 

 

 

 

FR-2165DS, 2135SW/

 

 

 

 

OTHER S-BND

 

 

 

ANT B

 

 

 

 

FR-2115, 2125/

 

 

 

 

OTHER X-BND/

 

 

 

 

FR-2165DS, 2135SW/

 

 

 

 

OTHER S-BND

 

 

7 SHIP’S TYPE *1

 

DEEP SEA/FISHING/

 

 

 

 

LONG LINE FISHING

 

 

8 RANGE UNIT *1

 

NM/KM/SM

 

 

9 CABLE LENGTH

 

500m/5000m

 

 

0 FACTORY DEFAULT *2

 

 

 

 

 

 

 

 

 

 

 

 

 

[INITIAL SETTING 1]

1 [FUNCTIONS(4)]

 

 

2 HL ALIGN

EBL 0.0°

 

 

 

3 TIMING ADJ

 

 

 

VRM 00.00

 

4 ANT HGT

5m/7m/10m/15m/

 

20m/30m/MORE

5 LOG PULSE

200P/NM

 

6 [OWN SHIP INFORMATION]

 

7 MBS

MBS TIMING VRM 0

 

MBS LEVEL EBL 0

8 ON TIME

000000.0H

 

9 TX TIME

000000.0H

 

0 [INITIAL SETTING(2)]

 

 

 

Press [0]

 

 

 

 

 

 

[INITIAL SETTING 2]

 

1 [INITIAL SETTING(1)]

 

 

2 LOG GYRO INPUT

LOG

 

 

PULSE/SERIAL DATA

 

GYRO

 

 

AD10/SERIAL DATA

3 OWN SHIP VECTOR

COMPASS/COURSE

4 KEY BEEP

ON/OFF

 

5 SCANNER STOPPED

ST-BY/TX

 

6 VIDEO SIG

ANALOG/DIGITAL

7 ALARM LEVEL

4/5/6/7

 

8 DISPLAY

MAIN/SUB

 

9 SECTOR BLKG

OFF/ON

 

 

000° →

000°

 

000° →

000°

0 [INITIAL SETTING(3)]

 

 

 

Press [0]

 

 

 

 

 

 

[INITIAL SETTING 3]

 

1 [INITIAL SETTING(2)]

 

 

2 TRAILS RESTART

OFF/ON

 

3 ECHO AVG W/O GYRO

OFF/ON

 

4 HEAD UP TB SCALE

DEG/16POINT

5 CTR ECHO STRETCH

OFF/ON

 

6 VIDEO CONTRAST

1/2/3

 

7 MAXIMUM RANGE

72/96/120

 

8 ECHO FULL COLOR *1

OFF/ON

 

9 INDEX LINES

2/3/6

 

0 [INITIAL SETTING(4)]

 

 

*1 For merchant vessel the settings are DEEP SEA, NM, COLOR. *2: For factory use.

3-5

Image 37
Contents Marine Radar B . N o . I M E 3 4 6 4 0 M Safety Instructions Power Switch Power Switch in AC Powered Display UnitTable of Contents Standard Supply Equipment ListsName Type Code No Qty Remarks Optional EquipmentSystem Configuration Mounting considerations Scanner UnitAssembling the scanner unit Be sure to remove the guide pinsFastening the radiator to the radiator bracket Fastening the scanner unit to the mounting platformScanner unit, front view Display Unit Mounting procedureBefore mounting the display unit Tabletop mountingStay Setting catch to hole in stay Console type mounting 11 How to dismount the PTU coverSeparating the control head Display unit modification procedureSeparate type control head kit Type OP03-151, No 13 Detaching the control head Control head modification procedureConnection of display unit to control head PlateAttachment of hood 15 How to attach KB fixing plateWiring Scanner unit, front view, cover removed Correct seating of waterproofing gasket Fabricating signal cable S03-75 =EMI cores Outer cores RFC-13 thick Inner cores RFC-10 thin Fabricating signal cable S03-74DPYCY-3.5 Fabricating the AC power cable suppliedCVV-S 82C Fabricating the DC power cable CVV-S 8 x 2C, optionLeading in cables to the display unit Cable fed from rear of display unit DefaultCables fed from bottom of display unit for console mount Cable fed from outside display unitM4X8 2 pcs ConnectionsConnectors on the INT Board Connectors on the INT BoardHow to attach NH connector Changing AC Power SpecificationAccessing Menus for Initialization and Adjustment Tuning InitializationAdjusting Video Signal Level Restoring default settingsPicture appears Deviated counterclockwise Heading AlignmentSuppressing Main Bang Adjusting Sweep TimingMagnetron heater voltage rating Confirming Magnetron Heater VoltagePress Radar Menu 0 0 0 Initial Setting MenusInitial SETTING2 menu Initial SETTING1 menuInitial SETTING3 menu OWN Ship Information menu Initial SETTING4 menuGyro Converter GC-8 Installation and connection of the Gyro Converter BoardGyro Converter Board 64P1106 DIP switch, jumper wire settings Connection of external power supplyDefault setting Gyrocompass type Frequency Setting method 1 by gyrocompass specificationsJP1 JP2 JP3 JP4 JP5 Setting method 2 by make and model of gyrocompassSW1 Setting the heading readout on the radar displayARP Board ARP-26 Installation of the ARP boardARP Board 18P9002B ARP board adjustmentARP Board ARP-26 Final checkTable top/console type RP Board RP-2610 Display pedestal Necessary parts RP-26-Z-2E Code no Separate type control head13 Display pedestal, front view Necessary parts PM-30 and OP03-150 Code no Performance Monitor PM-30Procedure Alarm KitNecessary parts OP03-156 Code no 16 Display unit, inside view AC-DC Conversion Kit Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page