Nordyne AND M5S, SERIES M1B installation instructions M1GH 077, 090 Models

Page 35

Figure 41. Standing Pilot with Induced Draft Furnace, M1GH 077, 090 Models

35

WIRING DIAGRAM

 

 

 

 

 

Standing Pilot With Induced Draft Furnaces,

 

 

 

 

 

M1GH 077, 090 Models.

 

NOTES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Incoming power must be polarized. Observe

 

 

BLOWER

 

 

 

 

 

 

 

 

color coding. (See furnace data label for

 

 

MOTOR

 

 

 

 

 

AUX. LIMIT

 

 

electrical information.)

 

 

 

 

HEATING

 

 

 

 

 

 

 

2. If any of the original wires (as supplied with

 

 

 

ONLY

 

 

W

 

BLUE

 

 

 

 

 

 

 

BLACK

 

BLACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the appliance) must be replaced, use 105˚C

 

 

 

 

R

 

 

 

 

 

 

Thermoplastic type wire or its equivalent.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON/OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONNECTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOUSING CAP

 

 

 

 

 

WHITE

 

 

 

 

 

 

 

 

 

 

BLACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRAY RED

 

WHITE

 

 

 

 

 

 

 

 

BLUE

 

 

 

 

 

 

 

BLUE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK

BLACK

 

 

 

 

 

 

 

 

FUSE3A

 

 

 

BLACK BLACK

 

4

6

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

5

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRAY

 

 

 

 

 

 

 

HI-LIMIT

 

FAN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK

 

 

 

 

 

 

BLACK

 

SWITCH

 

 

 

 

 

 

 

 

 

 

GRAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAN

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

1 2

 

 

 

 

 

 

 

 

TRANSFORMER R

 

24 V C

BLACK

 

COMBUSTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SUPPLIED BY

 

 

 

BLACK

 

 

 

 

 

L1

115 V N

 

 

 

 

INSTALLER

 

 

 

 

 

 

 

 

 

 

 

WHITE

 

 

 

 

 

 

 

 

ORANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHITE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRESSURE

NEUTRAL

 

 

 

ORANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

 

 

 

 

WHITE

 

 

 

 

 

 

 

BLACK

 

 

 

 

 

 

 

 

GRAY

 

 

 

 

 

 

 

 

 

 

 

GROUND

 

 

 

 

 

 

 

 

 

 

BLUE

 

 

 

 

SCREW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BUSHING

 

 

 

FURNACE ELECTRICAL BOX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GAS VALVE

 

 

 

 

 

 

 

LEGENDS

 

703888C

 

 

 

 

 

 

 

 

 

 

 

115V:

FIELD 115V:

FAN ON/AUTO

 

 

 

 

 

 

 

 

 

 

 

 

 

24V:

FIELD 24V:

(Replaces 703888B)

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02/99

Image 35
Contents For installation Installation InstructionsStanding Pilot Models Direct Ignition Models Oil Gun Models Homeowner Information Installer Information InformationReturn Air Connections Supply Air Connections Requirements and Codes Safety InformationCombustion and Ventilation Air Gas Piping and Gas Pipe Pressure TestingGeneral Installation SafetyALL Models Closet Alcove General InformationMinimum Clearances Blower AssemblyApplications Unit LocationSupply Air Connections Circulating AIR RequirementsReturn Air Connections Gas piping is not run in or through the return duct systemRequirements and Codes Furnace InstallationDetermine which duct connector to use from General InformationDuct Connector Sizes Standard Duct Connector Installation Cut-Out Dimensions for Standard Duct ConnectorsInstalling The Furnace Duct Connector TabsApplication Notes Roof Jack InstallationRequired ceiling and roof cut-out openings see Roof Jack SelectionSlant Deck Flashings Roof Jack Series If Roof Pitch is Slant Deck FactorSecure fl ashing with appropriate fasteners Installing The Roof JackInstallation of Transit-Mode Venting System Connect fl ue pipe to fl ue collar of furnace. See FigureElectrical Information Line Voltage WiringThermostat Length Unit to T’STAT Low Voltage WiringWire Heating Heating/Cooling Thermostat Wire GaugeImportant Notes Fuel Supply and PipingFuel line Hook-Up Oil Tank and Piping InstallationConversion to Propane LP Gas Leak CheckFuel Oil Type Honeywell Gas Valve High Altitude ConversionStanding Pilot Valve Lighting Instructions Standing Pilot ModelsOperating Instructions for Direct Ignition Models M1M Replace the furnace doorPilot Flame Standing Pilot Only Burner AdjustmentsFor oil, shut off all valves Replace the furnace door Combustion Air Factory Combustion Air SettingsElectrode Setting Oil Gun Only M1M Models with Direct Ignition Operating SequenceStanding Pilot Standing Pilot w/Induced Draft BlowersFurnace Controls & Functions Direct Ignition Furnaces Including Gas Gun M1B Series see , TroubleshootingStanding Pilot Models Page Cad cell is operational, replace the primary control Burner will not start and the LED indicator isOptional Accessories Cad Cell Resistance when Sensing flameControl Module Status Indicator M5S Series Control Module Status Indicators M1M SeriesRed LED Indicator Status Control Module Status Indicator M1BClean or replace the oil fi lter element at the oil tank MaintenanceInstaller Information Additional Oil Furnace MaintenanceManifold Pressure Natural Gas 3.5 w.c Burner Direct Blower TonsM1GB M1MCOrifi ce Size Nat. Gas Equivalent Orifice Sizes for High Altitude InstallationsOrifi ce Size Nat. Gas Orifi ce Size LP Output MbtuhGas Flow Rates Cubic Feet per Hour GAS InformationModels Wiring DiagramsM1GH 077, 090 Models M1GB 056, 070 Models Gas AtmosphericWiring Diagram Steady OFF No power Blinking Wiring Diagram Installation Address Installation / Performance Check List