OPERATING SEQUENCE
Standing Pilot
1 On a call for heat, the thermostat contacts close, supplying 24VAC to the gas valve.When energized, the valve steps open at a reduced
fl ow and opens fully within 14 seconds.
2.When the call for heat is satisfied, the thermostat contacts open, shutting off gas flow.
Standing Pilot w/Induced Draft Blowers
1.On a call for heat, the thermostat contacts close, supplying 24 VAC to the relay.
2.The relay contacts close and the induced draft motor energizes.
3.When the inducer starts, the air pressure switch closes at
4.When the call for heat is satisfied, the thermostat contacts open, the gas valve shuts off gas flow, and the induced draft blower stops.
M1M Models with Direct Ignition
1.On a call for heat, the thermostat contacts close, supplying 24 VAC between terminals C and W of the control module.
2.When the inducer starts, the air pressure switch closes at
3.After a 45 second purge, the ignitor is energized for a 30 second
the gas valve either remains open if fl ame is sensed, or closes if fl ame is not sensed.
5.If fl ame is not sensed, the sequence repeats four more times before a lockout occurs. To reset, wait 30 seconds and then interrupt the
24VAC power by turning the room thermostat below room temperature, then returning it to the original set point.
6.If fl ame does not establish on the 5th attempt (initial fire + 4
1hour. See Table 9 (page 29).
7.If a fl ame is present, the control energizes the main blower on heat speed 30 seconds after the gas valve opens.
8.When call for heat is satisfi ed the thermostat contacts open, the gas valve shuts off gas fl ow and the combustion blower remains on for a
30second
9.The main blower is
Oil Gun Furnace with Honeywell R7184 / Beckett 7505 Control - M5S Models
1.When a call for heat is initiated, there is a 2 to 6 second delay while the control performs a safe start check.
2.The ignition and motor are turned on and a fl ame should establish within a
3.If fl ame is not sensed within the
WARNING:
If furnace still doesn’t light, turn the furnace off as described above and call your technician. In the event of flashback or explosion, immediately shut off furnace and call your service technician.
4.After fl ame is established, the ignition remains on for 10 seconds to ensure fl ame stability. It then turns off.
5.The circulating air blower will energize after the temperature fan switch closes.
6.The furnace runs until the call for heat is satisfi ed.
7.The circulating air blower will
Gas Gun Models
1.On a call for heat, the furnace control begins an ignition sequence which lasts approximately 45 seconds.
2.After this sequence, the control module tests to see if fl ame is sensed. If it has, the furnace continues to heat until the thermostat is satisfi ed.
3.If the burner has not lit, the ignition sequence is repeated a maximum of two more times. If fl ame is not sensed after three attempts, the control enters Lockout and no further attempts to light the burner will occur. If Lockout occurs, contact a qualifi ed service technician for assistance.
24