Emerson SPS 4001B instruction manual Description and Specifications, Component Checklist, Overview

Page 7

Instruction Manual

IM-106-340AC-1, Rev. 1.0 April 2005

SPS 4001B

Section 1 Description and Specifications

COMPONENT

CHECKLIST

Figure 1-1. SPS 4001B Package

Component Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-2

A typical SPS 4001B Single Probe Autocalibration Sequencer should contain the items shown in Figure 1-1. Record the part number, serial number, and order number for the SPS 4001B on the back cover of this manual.

NOTE

The SPS 4001B operates exactly the same with either the Oxymitter 4000 Oxygen Transmitter or the Oxymitter 5000 Oxygen Transmitter with FOUNDATION fieldbus communications. Any references to the Oxymitter 4000 throughout this instruction manual also apply to the Oxymitter 5000.

1

2

Analytical

1.SPS 4001B

2.Instruction Manual

Analytical

37470004

OVERVIEW

The SPS 4001B provides the capability of performing automatic, timed or on

 

demand, calibrations of a single Oxymitter 4000 without sending a technician

 

to the probe site.

 

The SPS 4001B replaces the SPS 4000, a similar unit with exposed analog

 

devices mounted to a stainless steel support bracket. The operating

 

parameters of the SPS 4000 and SPS 4001B are identical. All SPS units

 

require additional calibration system components. These components,

 

available from Rosemount Analytical, are listed in Table 1-1.

http://www.processanalytic.com

Image 7
Contents SPS 4001B Single Probe Autocalibration Sequencer Page Table of Contents TOC-2 Essential Instructions SPS 4001B Single Probe Autocalibration SequencerPreface SymbolsDefinitions Component Checklist Description and SpecificationsOverview Specifications SpecificationsManifold Physical DescriptionCalibration Gas Flow Meter Pressure SwitchCalibration Gas Solenoids Circuit BoardTheory of Operation SPS 4001B Calibration Setup Overview Mechanical Installation Section InstallationReference Air Figure GAS ConnectionsCalibration Gas Figure Analytical Connections ElectricalGND SPS 4001B Overview Calibration Requirements Section OperationCalibration Gas Tanks Check Valve Liquid Carbonic GAS Corp Specialty GAS LaboratoriesTimed Interval CAL RecommendedSEMI-AUTOMATIC Calibration Fuse Replacement Maintenance and ServiceSPS 4001B, Exploded View Installation REMOVE/INSTALL ChassisRemoval Terminal Connections Solenoid Replacement Circuit Board ReplacementPressure Switch Replacement SPS 4001B Troubleshooting TroubleshootingRelay Failure SPS 4001B Fault Finding SPS 4001B Troubleshooting Flowchart Sheet 1 SPS 4001B Troubleshooting Flowchart Sheet 2 SPS 4001B Replacement Parts SPS 4001B Index No Part Number Description Calibration ComponentsSPS 4001B Appendix a Safety Data Safety Instructionsimportant Belangrijk Vigtigt SPS 4001B Tärkeää SPS 4001B Wichtig Importante Viktig SPS 4001B SPS 4001B Viktigt SPS 4001B Returning Material Appendix B Return of MaterialsSPS 4001B Index Index-2 Warranty IM-106-340AC-1, Rev .0 April SPS 4001B Serial no Order no