F9. Backup Functions

TERMINOLOGY

Backup:

You can back up some settings, such as voice selection and reverb type, so that they will not be lost when you turn off the power to the Clavinova.

If the backup function is turned on, the settings at power off are effective. If the backup function is turned off, the settings in memory are erased when you turn off the power. In this case, when you turn on the power to the unit, the default set- tings (the initial settings) will be used. (The factory setting default list is found on page 68.)

However, the backup settings themselves, and the con- tents of the user song recorder memory, are always backed up.

CAUTION

Even if the backup function is turned on via one of the functions described below, the data will be retained in memory for only about one week if the power is not turned on during this time. If the backup period is exceeded, all settings will be reset to their default values. If you want to retain the backup settings for longer peri- ods, be sure to turn the power on for a few minutes at least once a week.

You can turn the backup function on or off for each function group (each of the following sub-mode functions).

1.Engage Function mode and select .

2.Press the [+/YES] button to engage the backup function’s sub-mode, then use the [TEMPO/FUNCTION# ▼ ▲] buttons to select the desired sub-mode.

Press the [–/NO] or [+/YES] button to turn the backup function on or off.

Sub-mode

Voice

MIDI

Tuning

Others

Setting range: ON/OFF

Normal setting: OFF (all groups)

Description of sub-modes

Voice

Voice (Keyboard, Dual, and Split)

Dual (ON/OFF, Voice, and Dual Functions for each voice combination)

Split (ON/OFF, Voice, and Split Functions for each voice combination)

Reverb (ON/OFF, Type, and Depth for each voice)

Effect (ON/OFF, Type, and Depth for each voice)

Variation (for each voice)

Touch Sensitivity (including the FIXED volume)

Metronome (Beat, Volume <

 

 

settings>)

Preset Song Part Cancel Volume (

 

 

settings)

 

 

MIDI

The MIDI functions ( settings)

(expect for the )

Tuning

Transpose

 

 

 

 

 

 

 

 

 

Tuning (

 

settings)

 

 

Scale (including base note) (

 

settings)

 

Others

Other functions ( settings)

Factory Preset Recall

All Dual mode, Split mode, reverb, effect, touch sensitiv- ity, tuning settings, and the settings affected by the Backup Functions can be restored to their original fac- tory preset values by holding the C7 key (right-most key on the keyboard) while turning the [POWER] button ON. This also erases all user song recorder data, and sets all backup on/off settings (F9) to “OFF”. (The factory set- ting list is found on page 68.)

50CLP-F01Detailed Settings – [FUNCTION]

Image 50
Contents CLP-F01 Special Message Section Precautions Connections Reference TrademarksIntroduction AppendixTable of Contents Application Index Bench may be included or optional, depending on your locale AccessoriesTuning TransportingFeatures TransposeTo open the key cover Before Using the ClavinovaKey Cover To close the key coverTo replace the music rest Music RestTo position the music rest for use Turn the power on Turning the Power OnConnect the power cord Power indicatorUsing the Speaker Switch Setting the VolumeUsing Headphones option Memo Clavinova’s various functions Panel Controls and TerminalsTop panel ConnectorsPanel Controls and Terminals Display Listening to the Demonstration Tunes Play any of the 50 preset songs Listening to 50 Piano Preset SongsEngage Preset Song mode Stop playbackTurn off the playback part you wish to practice Exit from Preset Song modeHow to use the practice functions Start playback and playingLeft Pedal Start/Stop Repeat for 50 Preset Songs Will appear on the disSelecting Voices Using the PedalsSelecting & Playing Voices Damper Right PedalSoft Left Pedal Normal settingSostenuto Center Pedal Depth 0 no effect Adjusting Reverb DepthAdjusting Effect Depth Depth 0 no effect Depth 20 maximum effect depthChanging the volume when Fixed is selected Touch Sensitivity TouchTransposition Transpose TransposeExit Dual mode and return to normal play mode Combining Two Voices Dual modeEngage Dual mode Engage Split mode SplitSelect a voice for the right hand Exit Split mode and return to normal play modePress the Split button again so that its indicator goes out Select a voice for the left handAdjusting the time signature Using the MetronomeAdjusting the tempo Start the metronomeSelect a song for recording Make all the initial settingsRecording Your Performance Recording vs. SavingStart recording Engage Record modeSelect the record track Stop recordingRe-recording Track Recording to TrackEntire Song Individual TracksVoice selection Press the REC button to exit Record mode You can change the following initial settingsChange the settings via the panel controls Playing Back a Song Midi connectorsPlaying Back Recorded Songs Select the desired songAssigning the START/STOP function to the left pedal Useful Playback FunctionsTurning track playback on and off SynchroDetailed Settings Function Parameter ListSelect a function Basic Procedure in Function ModeEngage Function mode Use the -/NO +/YES buttonsOperation Example 2 F3.1 Dual Balance Do the following when you finish using the func- tionOperation Example 1 F1. Fine tuning of the pitch Display Value Setting rangeAbout Each Function Hz HertzPythagorean EqualPureMajor/PureMinor MeanToneDual Detune ResetSub-mode Dual Balance Voice 1 Octave Shift Voice 2 Octave ShiftRight Voice Octave Shift Left Voice Octave Shift Sub-mode Split PointSplit Balance Right Voice Effect Depth Left Voice Effect DepthSoft Pedal Effect Depth Sub-mode Left Pedal ModeKeyoff Sample Volume Sustain Sample Depth F6. Metronome Volume Sub-mode Midi Transmit Channel SelectionLocal Control ON/OFF Setting range ON/OFF Normal setting onMidi Receive Channel Selection Program Change ON/OFFPanel/Status Transmit ProcedureMidi Transmit Transpose Bulk Data DumpSetting range ON/OFF Normal setting OFF all groups Sub-mode Voice Midi Tuning OthersFactory Preset Recall Description of sub-modes VoiceAbout Midi Midi connectorsTo Host connector Midi cablesConnectors ConnectionsAUX in R, L/L+R jacks AUX in L/L+R jack or AUX OUT L/L+R jackConnecting a Personal Computer On the power to the computer first, then to the ClavinovaType of serial cables and connection pin assignments ConnectionConnection Clavinova Host Select switch settingSet the Clavinova Host Select switch to Midi Computer Troubleshooting Problem Possible Cause and SolutionInsert the rear panel center Keyboard Stand AssemblyRemoving the panels Fasten the rear panels securely Install the rear panels left and rightVoltage Selector Attach the fall-prevention bracketMove the Clavinova to an appropriate location After completing the assembly, please check the followingReview the assembly procedure and correct any errors Check the connectionPreset Voice List Voice Name Stereo Touch Dynamic Key-Off Voice DescriptionsWood Bass Voice Name Title Composer Demo Song ListPiano Voice Demo Description Voice Name Piano Voice DemoIndex 16, 29 Practicing a One-Hand Part Using 50 Preset Songs......20Soft Pedal 16, 24 Start/Stop playbackAppendix Function Backup GroupFunction number Default Backup Group CLP-F01Appendix Panel Data Transmit Panel Data ContentsMidi Master Volume General Midi Mode On Data format F0H 7EH XnH 09H 01H F7HMidi Parameter Change table Multi Part Effect Midi MapMidi Parameter Change table Effect Midi Implementation Chart ON/OFF Memo Memo Please Keep this Manual FCC Information U.S.A North America Clavinova Web site English only Yamaha Manual Library