Sierra SL-800 Returning Your Unit for Calibration or Service Shipment, Calibration Includes

Page 26

Calibration Includes

Cleaning (if required)

Valve adjustment (if required)

Battery capacity test

Internal computer program upgrade as necessary

Mechanical upgrades as necessary

Run-in test

Dynamic performance test

NIST-traceable calibration certificate

11.3Returning Your Unit for Calibration or Service

Prior to returning your Cal=Trak for service or calibration, please contact Sierra Instruments, Inc. for an RMA number. You can request an RMA number from any Sierra office or via our web site, www.sierrainstruments.com. Do not return your calibrator without an RMA number or your service may be delayed.

11.4Shipment

When shipping the Sierra Cal=Trak please ensure that the packaging is adequate to protect the instrument. When possible the Cal=Trak should be shipped in the optional storage case. Sierra Instruments, Inc. is not responsible for damage that occurs during shipment.

When transporting by air, the internal solenoid valve must be in the Open position to avoid possible cell damage. To open the valve, from the “Run Menu”, press the Stop button. The valve position may be verified by sealing both the inlet and the outlet fitting. The piston should move freely up and down the cylinder.

11.5Replacement Parts & Accessories

Part

Description

SL-800-B

Base Unit

SL-800-10

Low Flow Cell, range 5 sccm to 500 sccm

SL-800-24

Medium Flow Cell, range 50 sccm to 5 slpm

SL-800-44

High Flow Cell, range 500 sccm to 50 slpm

PEL-1600

Pelican case with foam insert, fits 1 base, 1 cell & accessories

PEL-1650

Pelican case with foam insert & wheels, fits 1 bases, 2–3 cells & accessories

800 BAT

Battery, 6V lead-acid

UNIVERSAL

120/240V battery charger; please specify plug configuration

FOAM-1600

Replacement foam insert for Pel-1600

FOAM-1650

Replacement foam insert for Pel-1650

LT-CABLE

Leak test cable

CA-23

RS-232 cable for PC connection

26

Image 26
Contents Cal=Trak SL-800 Primary Gas Flow Calibrator Worldwide Locations to Serve You Table of Contents Page General Description Theory of OperationIdealized Automatic Piston Prover Cal=Trak Layout Unpacking Checklist Your Cal=Trak SL-800 Base IncludesEach of Your Cal=Trak SL-800 Flow Cells Includes Cal=Trak Measurement Cycle Cal=Trak Installation Attaching & Removing Flow CellsConnecting the Cal=Trak to a Flow Source Attaching Flow CellsInitial Pressure Pulse Timing KPa Begins Ends Comparison vs. Calibration Application PrecautionsInventory Dead Volume Initial Pressure PulseSetup for Piston or Bell Provers Alternative Setup for Piston Provers Vacuum Comparison of Cal=Trak with Piston or Bell ProversSetup for LFEs Comparison of Cal=Trak with Sonic Nozzle Transfer StandardsVacuum Setup for Sonic Nozzle Transfer Standard Calibration of Mass Flow Controllers MFCsCalibration of Mass Flow Meters MFMs Calibration of Rotameters Variable Area Flow MetersTurning the Cal=Trak On Charging the Cal=Trak BatteryOperating Instructions Turning the Cal=Trak OffGeneral Menu Navigation Cal=Trak Keypad How To Use the Cal=Trak KeypadLow Battery Indicator Taking Readings Factory Default SettingsParameters Factory Settings Optional Settings Setting User Preferences Option 1, Sensor FactorSetup Menu 2, Reading Type, # in Average & Minutes/Reading Setup Menu 4, Date, Time & Battery VoltageOption 2, Time Setup Menu 5, Date & Time FormatsOption 1, Date Option 3, Auto OffMaintenance Battery SystemBattery Maintenance & Storage Quality Assurance Leak Test Procedure To Initiate the Leak TestCalibration Leak Test Illustration Leak Test in ProgressCalibration Includes Returning Your Unit for Calibration or Service ShipmentReplacement Parts & Accessories Part DescriptionAdditional Information Limited Warranty Piston Error appears on display Charge LED does not light when charger pluggedSettings have been lost or seem to have changed Unit suddenly turns offDuring Leak Test, Leakage 9.999 ccm appears on display Piston does not move when the Read or Auto is pushedWhen taking readings, the flow seems off Resetting the Cal=Trak Contact Sierra for AssistanceModel Optimum Flow Range Flow Cell Standardized 15-30CRequirements Installation Operating Instructions for Cal=Soft SoftwareIntroduction Worksheet descriptionsSetup Cal=Trak IntroductionSetup DUT Setup Cal=SoftPage Page Automatic Flow Calibration Using Sierra 100 Series MFC Serial Port Configuration Issue Software TroubleshootingSerial Port Selection Issue