Mounting According to the Type of PV rack

Minimum distance between module edge to PV rack is 10.236 inch (260mm).

 

Mounting Type

 

Clamping Type (Long Side)

1

2

2

1

Clamping Range

7.874 inch (200mm)

 

 

 

 

11.811 inch

11.811 inch

 

 

 

 

(300mm)

(300mm)

1

2

2

1

 

 

Use four mounting holes on two opposite sides.

Use four clamps on the long

frame.

Clamping Type (Short Side)

Center ± 3.937 inch (100mm)

Clamping Range:

From module Edge

to 10.630 inch (270mm)

Center ± 3.937 inch (100mm)

Use four clamps on the short frame and two clamps at the center of long frame.

This method is not tested by IEC/UL.

Clamping Range:

From module Edge to 4.724 inch (120mm)

Use four clamps on the short frame.

This installation is allowed in the following cases:

1.Slope roof: If module is installed parallel to the rooftop.

2.Flat roof: If installed with an additional stand such as wind shield or deflector.

Please check that PV rack does not interfere with a micro inverter.

11

Image 11
Contents AC Module System Installation Instructions Revisions Table of ContentsImportant Safety Instructions SafetySafety Symbols For Communication Gateway Indoor use only Circuit SymbolsFCC Guidelines For Micro inverter & Communication GatewayCommunication gateway IntroductionAdvantages of AC Module System AC Module SystemAC Module Before InstallationInspecting the Area of Installation Measuring AC Voltage of the Utility Inspecting Components of the AC ModuleWiring Diagram of AC Module System Mounting the AC module Installing the AC Junction Box and PV RackProduct Specification Fix AC module to the PV rack in the following order Mounting According to the Type of PV rack Trunk cable usage and maintenance Connecting AC Modules Trunk CableTrunk connector insertion Trunk connector removalPage Checking Accessory Checking the AccessoriesCable Usages According to AC Junction Box Locations Grounding Samples for Grounding Male transition cable Connect the general AC cables in the following order AC output single phase 240VACAC output three phase 208VAC merge type AC output three phase 208VAC split type Operation MaintenanceChecking Components of the Communication Gateway EnerBoxTM Communication GatewayLED status Troubleshooting Connecting to the Communication GatewayConfiguring the Installation App Checking installed AC modules LGElectronics Setting the grid configuration Checking conditions of installed AC modulesWebsite Setting System ConfigurationDiagram Details AccessoriesSection 240VAC 208VAC Product SpecificationsAC Module Parameter Section ValueDimensions Internal Communication with AC module EnerBoxRange Clearing Time s Response to Abnormal ConditionsDedicated Cables Disclaimer of Liability WarrantyTransporting and Storage Contact