6-3 Response to Abnormal Conditions
IEEE 1547 (Default)
Parameter | Range | Clearing Time (s) | |
| V < 60V | < 0.16 | |
Phase Voltage | 60V ≤ V < 106V | < 2.00 | |
132V ≤ V < 144V | < 1.00 | ||
| |||
| V ≥ 144V | < 0.16 (< 0.016, Hawaii mode - TOV)1) | |
Frequency | > 60.5Hz | < 0.16 | |
< 59.3Hz (< 57 Hz, Hawaii mode)1) | < 0.16 | ||
|
1)For setting to Hawaii mode, refer to Chapter
Note 1 : This test is performed in nominal conditions, except for test parameter.
Note 2 : After clearing, if grid returns to the normal state, it takes about 5 minutes for operation of the AC module.
|
|
|
|
|
| Trunk |
|
| Type |
| |
Cable | Max. Voltage |
| 600V |
Max. Current |
| 20A | |
|
| ||
| Size |
| 12AWG |
Connector | Max. Voltage |
| 300V |
Max. Current |
| 20A | |
|
| ||
|
| Drop |
|
| Type |
| |
Cable | Max. Voltage |
| 600V |
Max. Current |
| 5A | |
|
| ||
| Size |
| 18AWG |
Connector | Max. Voltage |
| 300V |
Max. Current |
| 5A | |
|
| ||
|
| Certification |
|
| UL9703, UL6703A |
| |
|
| Dimensions |
|
| 400 mm |
| |
| (95.75 inch) |
| |
| 53 mm | 31.5 mm |
|
| (2.09 inch) | (1.24 inch) |
|
122 mm |
|
|
|
(4.80 inch) |
| 1,200 mm | 66 mm |
|
| (47.24 inch) | (2.60 inch) |
34 |
|
|
|