Step 3. Checking installed AC modules
|
|
| LGElectronics |
| |
|
|
|
|
|
|
1 | After connecting the AC module system at the grid, | 2 | If all are displayed, press the Registration button. | ||
| press MAC Address List. Within 15 minutes, |
| Otherwise, press Back button. After waiting 2~3 | ||
| check that all installed AC modules are displayed. |
| minutes, check that all modules are synced. | ||
| After 15 minutes, the AC modules may enter sleep |
|
|
| |
| mode. |
|
|
|
※The PLC LED will turn to orange during updates. Do not press the Registration button. Allow about 5 seconds per module for update.
※If modules are still not detected, turn off then turn back on the circuit breaker for AC module system to wake up modules in sleep mode. If this does not work, try plugging in the PLC cable to a different outlet near the distribution panel.
3Go to the next step and check that all modules have been registered.
•Hitting the Registration button will configure the AC module system group that is visible to that gateway only. Any AC modules not registered to the group need to be
•Add, Import, Export buttons can be used when replacing the gateway.
Note 1.
Adding AC modules:
If you pressed Registration button before listing all AC modules, or you need to add the unlisted AC module, follow steps below.
1Enter LGElectronics (initial password) on the blank box in figure and press EnerBox Group chage button to return the gateway into the initial condition.
Check PLC LED. It should turn red.
2Press the Back button. Wait for a minute and check that the PLC LED has changed green. Then, press MAC Address List and check if the additional AC modules have been listed.
※If you can’t check the additional AC modules, connect the gateway to another outlet near the distribution panel and search for the unlisted AC modules.
3Press Registration button to finish.