LG Electronics LGENBOX-01, LGxxxA1C-B3 Checking the Accessories, Checking Accessory

Page 14

Step 4. To connect AC modules in different rows, use the extension cable.

(Refer to the next page under Cable Usages According to AC Junction Box Locations)

Checking the Accessories

 

 

Female + Female

Male + Male

Female + Male

extension cable

extension cable

extension cable

Step 5. Remove the dust cover of the female connector of the last AC module and seal with end cap to ensure waterproofing and dust prevention. Insert the end cap into the trunk male connector in the arrow direction until you hear a clicking sound. Seal the end part by referring to the following drawing.

 

If trunk male

 

connector is the end part

 

 

If trunk female

 

connector is the end part

 

 

Checking Accessory

Male end cap

Female end cap

Step 6. Check the cables to verify they have not been pulled too tight or are hanging too loose. If necessary, fixate them using the cable fixing holes on PV module frame with fixing holders, such as cable ties, so that the cables do not touch the ground.

Trunk connector and end cap serve to prevent collection of dust and waterproof functions.

14

Image 14
Contents AC Module System Installation Instructions Table of Contents RevisionsImportant Safety Instructions SafetySafety Symbols For Micro inverter & Communication Gateway Circuit SymbolsFCC Guidelines For Communication Gateway Indoor use onlyAC Module System IntroductionAdvantages of AC Module System Communication gatewayAC Module Before InstallationInspecting the Area of Installation Inspecting Components of the AC Module Measuring AC Voltage of the UtilityWiring Diagram of AC Module System Mounting the AC module Installing the AC Junction Box and PV RackProduct Specification Fix AC module to the PV rack in the following order Mounting According to the Type of PV rack Trunk connector removal Connecting AC Modules Trunk CableTrunk connector insertion Trunk cable usage and maintenancePage Checking the Accessories Checking AccessoryCable Usages According to AC Junction Box Locations Grounding Samples for Grounding Male transition cable AC output single phase 240VAC Connect the general AC cables in the following orderAC output three phase 208VAC merge type AC output three phase 208VAC split type Maintenance OperationEnerBoxTM Communication Gateway Checking Components of the Communication GatewayConnecting to the Communication Gateway LED status TroubleshootingConfiguring the Installation App Checking installed AC modules LGElectronics Checking conditions of installed AC modules Setting the grid configurationSetting System Configuration WebsiteAccessories Diagram DetailsParameter Section Value Product SpecificationsAC Module Section 240VAC 208VACDimensions EnerBox Internal Communication with AC moduleRange Clearing Time s Response to Abnormal ConditionsDedicated Cables Contact WarrantyTransporting and Storage Disclaimer of Liability