LG Electronics LGxxxA1C-B3 Product Specifications, AC Module, Parameter Section Value, VAC 208VAC

Page 31

6 Product Specifications

6-1 AC Module

DC Input

Parameter

Section

 

Value

 

 

 

 

 

 

Power

Max.

295 W

300 W

305 W

Tolerance

3 %

3 %

3 %

 

Voltage

Open Circuit

39.7 V

39.8 V

40.0 V

 

 

 

 

Max Power Point

31.8 V

32.0 V

32.1 V

 

Current

Short Circuit

9.85 A

9.98 A

10.10 A

 

 

 

 

Max Power Point

9.28 A

9.40 A

9.52 A

 

Efficiency

Relative Reduction

 

< 2.0 %

 

 

 

 

 

Note : Relative efficiency reduction in respect to irradiance.

 

 

 

Note : Rated electrical characteristics are within 10 percent of above figures.

 

 

PV module was measured at STC. (Standard Test Condition: Irradiation 1,000W/m2, Cell temp. 77ºF(25),

1.5AM)

 

 

 

 

 

 

 

 

AC Output

 

 

 

 

 

 

 

 

Parameter

 

Section

240VAC

 

208VAC

 

 

 

 

 

 

 

AC Continuous1)

280W(@DC Module 295W) /

285W(@DC Module 300W) /

Power

 

290W(@DC Module 305W)

 

 

Inverter Rated Continuous

305 W

 

300W

 

 

 

 

 

 

Voltage

 

Rated

240 V (211 ~ 264 V)

 

208 V (187 ~ 229 V)

Current

 

Rated

1.27 A

 

1.44 A

 

 

 

 

 

 

Max Fault Current

 

77 A

 

 

 

Frequency

 

Nominal

60 Hz (59.3 ~ 60.5 Hz)

 

 

 

 

 

 

Extended2)

57.0 Hz ~ 60.5 Hz

 

 

 

Power Factor

 

> 0.95

 

 

 

 

CEC Weighted Efficiency

96.5 %

 

96.0 %

(California Energy Commission)

 

 

 

 

Max. Number of AC Modules3)

12 units

 

11 units

1)AC Continuous = Max Input DC Power x CEC Efficiency.

2)For setting frequency rage, refer to Chapter 4-3. Configuring the Instalation App - Step 5.

3)For details, refer to Chapter 3-10. Connecting AC Module Array to Distribution Panel.

 

Protection

 

 

Ground Fault Detection and Interrupt (GFDI)

Applied

Fuse (Internal of the Micro Inverter)

2A

CAUTION : FOR CONTINUED PROTECTION AGAINST RISK OF FIRE,

REPLACE ONLY WITH SAME TYPE AND RATING OF FUSE.

Over Current Protection Device (OCPD)3)

20A

3)For details, refer to Chapter 3-10. Connecting AC Module Array to Distribution Panel.

31

Image 31
Contents AC Module System Installation Instructions Revisions Table of ContentsSafety Symbols SafetyImportant Safety Instructions For Communication Gateway Indoor use only Circuit SymbolsFCC Guidelines For Micro inverter & Communication GatewayCommunication gateway IntroductionAdvantages of AC Module System AC Module SystemInspecting the Area of Installation Before InstallationAC Module Measuring AC Voltage of the Utility Inspecting Components of the AC ModuleWiring Diagram of AC Module System Product Specification Installing the AC Junction Box and PV RackMounting the AC module Fix AC module to the PV rack in the following order Mounting According to the Type of PV rack Trunk cable usage and maintenance Connecting AC Modules Trunk CableTrunk connector insertion Trunk connector removalPage Checking Accessory Checking the AccessoriesCable Usages According to AC Junction Box Locations Grounding Samples for Grounding Male transition cable Connect the general AC cables in the following order AC output single phase 240VACAC output three phase 208VAC merge type AC output three phase 208VAC split type Operation MaintenanceChecking Components of the Communication Gateway EnerBoxTM Communication GatewayLED status Troubleshooting Connecting to the Communication GatewayConfiguring the Installation App Checking installed AC modules LGElectronics Setting the grid configuration Checking conditions of installed AC modulesWebsite Setting System ConfigurationDiagram Details AccessoriesSection 240VAC 208VAC Product SpecificationsAC Module Parameter Section ValueDimensions Internal Communication with AC module EnerBoxDedicated Cables Response to Abnormal ConditionsRange Clearing Time s Disclaimer of Liability WarrantyTransporting and Storage Contact