Step 4. Checking conditions of installed AC modules
1Enter into AC Module Status to check the operating status of the AC module system.
2If all AC modules status is not updated, press Back button and wait about 15 minutes until the next sync period. (Information is updated every 15 minutes.)
3Enter into AC Module Status to check the operating status of the AC module system again.
• If ground fault occurs, AC module automatically detects and stops.
Step 5. Setting the grid configuration
1Enter into Grid Configuration and set the grid configuration to suit your environment. If the grid configuration is wrong, AC modules may not operate correctly.
2Press the Set button. It takes about 5 seconds per module for setting.
3Press the Update button and check that the selected grid setting is correct. If all AC modules are not updated, please try again.