4 EnerBoxTM Communication Gateway
After installation of AC modules is completed, next step is to install the communication gateway for monitoring. Before installing the gateway, adhere to the following notices:
Notice
•For reliable communication, it is recommended that the gateway is installed near the distribution panel.
•To avoid damage and failure of the gateway, do not use at temperatures outside of 32 ~ 104°F (0 ~ 40°C).
•To avoid damage of the gateway, install the gateway indoors only.
•To avoid malfunction of the gateway, be sure to use only the enclosed adapter and cables.
•To avoid risk of the electric shock, do not disassemble or expose to pressure.
•To avoid risk of the electric shock, do not bend or cut cables used to connect to the gateway.
•Do not expose to water.
•Only clean with a dry cloth.
4-1 Checking Components of the Communication Gateway
1 | 5 |
|
2 | 7 | |
3 |
| |
| 11 | |
4 |
| |
| 10 | |
6 |
| |
8 | 9 | |
|
|
Declaration of Conformity
Trade Name : LG
Model :
Responsible Party : LG Electronics Inc.
Address : 1000 Sylvan Ave, Englewood Cliffs, NJ 07632, U.S.A
TEL :
1Power Port (12V / 1A)
Powers communication gateway via AC adapter.
2PLC IN Port
Delivers signal of AC modules to communication gateway via AC cable.
3LAN Port
Connects to network via LAN cable. (Green light will turn on if connected properly.)
4
Connects to serial network via
5Power LED (Green)
Green when AC adapter is connected properly.
6GFDI LED (Red)
Turns on in case of ground fault in solar system.
7PLC LED (Green / Red)
Green: AC cable is connected properly.
Red: Connection disruption.
8Wireless LAN LED (Green / Red)
Green: Wireless communication is operating properly.
Red: Problem with wireless communication.
9USB Port (Charge Only)
Charge smart device via supplied USB.
10Gateway Reset Pin
Used to reset gateway if malfunctioning.
11Wireless LAN Reset Pin
Used to reset WAP password.
※ Default password : 87654321
WARNING
•This product contains chemicals known to the California State of to cause cancer and birth defects or other reproductive defects. Wash hands after handling.
•EnerBox warranty void if cover removed. No serviceable parts inside. Refer servicing to qualified personnel.
•To avoid communication interference, do not connect the product to power strips, surge protectors, or surge
23