Teledyne OT-3 Spare Parts List, Trace Oxygen AnalyzerAppendix, Analytical Instruments

Page 45

Trace Oxygen AnalyzerAppendix

A.2

Spare Parts List

QTY

P/N

DESCRIPTION

1

C65220-A

PC Board, Main (std.)

1

C70740-A

PC Board, Power Supply AC (std.)

1

C6689-B-2C

Micro-Fuel Cell, class B-2C, or

1

C6689-A-2C

Micro-Fuel Cell, class A-2C, (CO2 type), or

1

B 71875

Micro-fuel Cell Insta-Trace, B-2C type, or

1B 73016 Micro-fuel Cell Insta-Trace, A-2C (CO2 type)

2F1130 Fuse (AC), ½A, 250 VAC, IEC Type T, 5 x 20mm

1

C-74162-A

PC Board, Power Supply DC (std.)

1

F1605

Filter Elements (5 elements)

1

R2533

Restrictor (0.4 SCFH @ 4 psig)

1

R2588

Regulator

 

1

O182

O-Ring std. OT-3 Cell Holder

1

C74050A

Acid Gas Scrubber

1*

C73514A

3300/OT-3 Control Unit, AC, std.

1*

C73514B

3300/OT-3

Control Unit, AC, RS232

1*

C73514C

3300/OT-3

Control Unit, DC, std

1*

C73514C

3300/OT-3

Control Unit, DC, RS232

1

F51

Fuse (DC Units) 1/2 Amp Micro

* Depends on options chosen at time of purchase

IMPORTANT: Orders for replacement parts should include the part number and the model and serial number of the system for which the parts are intended.

Send orders to:

TELEDYNE ELECTRONIC TECHNOLOGIES

Analytical Instruments

16830 Chestnut Street

City of Industry, CA 91749-1580Telephone: (626) 934-1500

Fax: (626) 961-2538 or your local representative.

Web: www.teledyne-ai.com

Teledyne Analytical Instruments

37

Image 45
Contents Teledyne Analytical Instruments Trace Oxygen AnalyzerCopyright 2000 Teledyne Analytical Instruments Model OT-3Specific Model Information Important Notice Trace Oxygen Analyzer Table of Contents Maintenance OperationAppendix Front Panel List of FiguresIntroduction Main Features of the AnalyzerOverview Trace Oxygen Analyzer IntroductionIntroduction OT-3 Front Panel DescriptionFunction Keys Measurement Parameters Readout Rear Panel DescriptionRear Panel AC Version Operational Theory Installation OT-3Introduction Micro-fuel Cell SensorAnatomy of a Micro-fuel Cell Trace Oxygen Analyzer InstallationElectrochemical Reactions Effect of Pressure Calibration CharacteristicsGeneral ElectronicsBlock Diagram of the Signal Processing Electronics Signal ProcessingInstallation OT-3 Unpacking the Analyzer InstallationInstalling the Micro-fuel Cell Location and MountingElectrical Connections Analog Outputs Primary Input PowerContact ID for Failsafe Relay Operation Alarm RelaysRelay Ratings Solid State Relay Output Gas ConnectionsGas Connections Sample System OT-3 Sample System Installation ChecklistInstallation OT-3 Teledyne Analytical Instruments Trace Oxygen Analyzer Operation OperationUsing the Function and Data Entry Buttons Setting the Analysis RangesOperation OT-3 Set Alarm Setting the Alarm SetpointsHI Range LO RangePower Failure Alarm Alarm DelayKeypad Lockout Calibration Selecting a Fixed Range or AutorangingSupplementary Information Displaying Percent & PPM on the LED DisplayOperation OT-3 Maintenance Trace Oxygen Analyzer MaintenanceReplacing the Fuse Sensor Installation or Replacement Maintenance OT-3When to Replace a Sensor Removing the Micro-fuel Cell Ordering and Handling of Spare SensorsInstalling a Micro-fuel Cell Cell Warranty Conditions Specifications AppendixAppendixOT-3 Spare Parts List Trace Oxygen AnalyzerAppendixAnalytical Instruments Reference Drawing MiscellaneousAppendix OT-3 Trace Oxygen Analyzer Index IndexNo Pass Index OT-3Website address Index OT-3 Teledyne Analytical Instruments