Teledyne OT-3 operating instructions Trace Oxygen Analyzer Index

Page 47

Trace Oxygen Analyzer

Index

 

 

 

Index

accuracy, 2, 36

data entry buttons, 24

address. See company address

data entry keys, 3

alarm

DELAY, 27

connection, 16

DELAY function, 27

delay, 26

diffusion membrane, 7

HI, 16

digital display, 3

LO, 16

digital meter, 2

power failure, 2, 26

digital to analog converter, 10, 12

SET ALARM 1, 25

display, 36

SET ALARM 2, 26

drain

specifications, 36

filter, 19

alarm 1, 17

drain valve, 20

alarm 2, 17

drawing list, 38

alarm indicator, 27

E to I converter. See voltage to current

alarm indicator LED, 2

electrical connections, 14

analog concentration signal, 12

electrical potential, 6

analog to digital converter, 10, 11

electrochemical device, 6

analysis mode, 23, 24

electrochemical transducer, 6

analysis range. See range

electrolyte, 6, 7, 13, 33

analysis ranges. See range

electron transfer, 9

anode, 6, 7, 8

failsafe operation, 16, 18

autoranging, 28

false alarms, 30

auto-ranging, 2

features, 1

back diffusion, 20

filter

blinking alarm indicator, 29

bypass, 1

blinking display, 27

coalescing, 1, 19, 20

concentration, 29

flow restrictor, 1, 21

calibration, 9, 28

flowmeter, 1, 20

calibration mode, 24

forced time-out, 29

cathode, 6, 7, 8, 9

front panel, 2, 23

cell block, 1, 18

function keys, 3

cell failure, 32

fuse block, 15

cell output, 8

fuse holder, 4, 31

cell warranty, 35

fuse replacement procedure, 31

Class 1 Div 1, 18

gas connection, 18

coalescing filter. See filter

gas selector switch, 20

company address, 37

half reaction. See reaction

configuring the OT-3, 23

hazardous location, 17

contaminants, 8, 13, 20

HI Range, 25

control unit, 6

hydroxyl ion, 8

copyright, ii

installation, 13

current generation, 11

installation checklist, 21

current output. See output

Insta-Trace, 1

Teledyne Analytical Instruments

39

Image 47
Contents Teledyne Analytical Instruments Trace Oxygen AnalyzerCopyright 2000 Teledyne Analytical Instruments Model OT-3Specific Model Information Important Notice Trace Oxygen Analyzer Table of Contents Appendix MaintenanceOperation Front Panel List of FiguresTrace Oxygen Analyzer Introduction Main Features of the AnalyzerIntroduction OverviewIntroduction OT-3 Front Panel DescriptionFunction Keys Measurement Parameters Readout Rear Panel DescriptionRear Panel AC Version Micro-fuel Cell Sensor Installation OT-3Operational Theory IntroductionAnatomy of a Micro-fuel Cell Trace Oxygen Analyzer InstallationElectrochemical Reactions Effect of Pressure Calibration CharacteristicsGeneral ElectronicsBlock Diagram of the Signal Processing Electronics Signal ProcessingInstallation OT-3 Unpacking the Analyzer InstallationElectrical Connections Installing the Micro-fuel CellLocation and Mounting Analog Outputs Primary Input PowerContact ID for Failsafe Relay Operation Alarm RelaysRelay Ratings Solid State Relay Output Gas ConnectionsGas Connections Sample System OT-3 Sample System Installation ChecklistInstallation OT-3 Teledyne Analytical Instruments Trace Oxygen Analyzer Operation OperationOperation OT-3 Using the Function and Data Entry ButtonsSetting the Analysis Ranges LO Range Setting the Alarm SetpointsSet Alarm HI RangePower Failure Alarm Alarm DelayKeypad Lockout Calibration Selecting a Fixed Range or AutorangingSupplementary Information Displaying Percent & PPM on the LED DisplayOperation OT-3 Replacing the Fuse MaintenanceTrace Oxygen Analyzer Maintenance When to Replace a Sensor Sensor Installation or ReplacementMaintenance OT-3 Removing the Micro-fuel Cell Ordering and Handling of Spare SensorsInstalling a Micro-fuel Cell Cell Warranty Conditions AppendixOT-3 Specifications Appendix Analytical Instruments Spare Parts ListTrace Oxygen AnalyzerAppendix Appendix OT-3 Reference DrawingMiscellaneous Trace Oxygen Analyzer Index IndexNo Pass Index OT-3Website address Index OT-3 Teledyne Analytical Instruments