ESSENTIAL INSTRUCTIONS

READ THIS PAGE BEFORE PROCEEDING!

Rosemount Analytical designs, manufactures and tests its products to meet many national and international standards. Because these instruments are sophisticated technical products, you MUST properly install, use, and maintain them to ensure they continue to operate within their normal specifications. The following instructions MUST be adhered to and integrated into your safety program when installing, using, and maintaining Rosemount Analytical products. Failure to follow the proper instructions may cause any one of the following situations to occur: Loss of life; personal injury; property damage; damage to this instrument; and warranty invalidation.

Read all instructions prior to installing, operating, and servicing the product.

If you do not understand any of the instructions, contact your Rosemount Analytical repre- sentative for clarification.

Follow all warnings, cautions, and instructions marked on and supplied with the product.

Inform and educate your personnel in the proper installation, operation, and mainte- nance of the product.

Install your equipment as specified in the Installation Instructions of the appropriate In- struction Manual and per applicable local and national codes. Connect all products to the proper electrical and pressure sources.

To ensure proper performance, use qualified personnel to install, operate, update, program, and maintain the product.

When replacement parts are required, ensure that qualified people use replacement parts specified by Rosemount. Unauthorized parts and procedures can affect the product’s per- formance, place the safe operation of your process at risk, and VOID YOUR WARRANTY. Look-alike substitutions may result in fire, electrical hazards, or improper operation.

Ensure that all equipment doors are closed and protective covers are in place, except when maintenance is being performed by qualified persons, to prevent electrical shock and personal injury.

The information contained in this document is subject to change without notice.

Emerson Process Management

Rosemount Analytical Inc.

Process Analytic Division

1201 N. Main St. Orrville, OH 44667-0901 T (330) 682-9010

F (330) 684-4434

e-mail: gas.csc@EmersonProcess.com http://www.processanalytic.com

Image 2
Contents World Class Essential Instructions Summary Highlights of ChangesEffective October, 1995 Rev Effective June, 1996 RevEffective May, 1997 Rev PageSummary Effective February, 1998 Rev PageSummaryTable of Contents World ClassList of Illustrations Typical System PackagePreface DefinitionsWorld Class Overview Component Checklist of Typical System Package ContentsSection Description System Configuration FeaturesTypical System Installation Existing Electronics Heater Power SupplyProbe Head Wiring ProbeInstallation Section InstallationEither make necessary repairs or install Oxygen Analyzer ProbeProbe Installation Sheet 1 Probe Installation Sheet 2 Probe Installation Sheet 3 Probe Installation Sheet 4 Probe Installation Sheet 5 Service Required Orienting the Optional Vee DeflectorElectrical Installation of Heater Power Supply Heater Power Supply Installation Electrical ConnectionsSelection JM1 Fuses JM2 World Class Section Setup Electronics SetupModel 218A Electronics Setup G02 G04Heater Set Point Adjustment Model TC200 Veritrim Electronics SetupEprom Replacement Model 132 Digital Electronics Setup Main PCB Model 132 Eprom ReplacementSection Troubleshooting System TroubleshootingWorld Class Section Return of Material World Class Section Appendices World Class Oxygen Analyzer Probe General Figure A-2. Main Probe ComponentsTable A-1. Specifications for Oxygen Analyzing Equipment.1 Probe Tube Assembly Probe Assembly ExteriorCell and Flange Assembly Snubber Diffusion AssemblyInner Probe Assembly Cell GeneralProbe Junction BOX Cable AssemblyAbrasive Shield Assembly Probe OptionsView a Figure A-8. Ceramic Diffusion/Dust Seal Assembly Ceramic Diffusion AssemblyBypass Probe Options Probe Mounting Jacket OptionsFigure A-13. Bypass Probe Option Sheet 1 Figure A-13. Bypass Probe Option Sheet 2 Extended Temperature By-Pass Arrangements 2400 F 1300 C Group Code DescriptionTable A-2. Fault Finding Symptom Check Remedy Probe TroubleshootingProbe Faults OverviewWorld Class Figure A-14. Flowchart of Probe Related Problems, #1 Figure A-15. Flowchart of Probe Related Problems, #2 Cell Replacement Probe RecalibrationFigure A-16. Cell Wiring Connection General Element ReplacementOptional Ceramic Diffusion World Class Replacement of Contact Thermocouple Assembly Figure A-19. Probe Junction Box Mechanical ConnectionsContact Heater Screws Not Shown Thermocoupler World Class Figure A-22. Oxygen Analyzer Probe, Cross-Sectional View Figure A-23. High Temperature Corrosive Environment Kit Replacement Parts Figure A-10 4841B03G02 Stainless Steel Diffuser Assembly Appendix B, REV HPS 3000 Heater Power Supply Description Front SideTable B-1. Specifications for Heater Power Supply Theory of OperationHPS 3000 Troubleshooting Overview HPS 3000 TroubleshootingSymptom Figure B-4. HPS Troubleshooting Flowchart, #1Figure B-5. HPS Troubleshooting Flowchart, #2 Figure B-6. HPS Troubleshooting Flowchart, #3 Mother Board Replacement Fuse ReplacementTransformer Replacement Daughter Board Replacement Figure B-7. Heater Power Supply, Exploded View Table B-2. Replacement Parts for Heater Power Supply Part Number DescriptionWorld Class Section Index World Class Warranty World Class 3000 Probe Serial No Order No HPS
Related manuals
Manual 88 pages 63.05 Kb Manual 60 pages 24.1 Kb Manual 88 pages 36.41 Kb Manual 32 pages 13.16 Kb Manual 22 pages 3.64 Kb Manual 184 pages 52.9 Kb

3000 specifications

The Emerson 3000 is a cutting-edge control system designed to enhance the efficiency, reliability, and precision of industrial operations. Employed across various sectors such as oil and gas, pharmaceutical, food and beverage, and power generation, the Emerson 3000 has gained recognition for its robustness and versatility.

One of the main features of the Emerson 3000 is its advanced process control capability. With integrated control algorithms, it can optimize complex processes in real-time, resulting in significant improvements in production rates and reduced operational costs. The system's predictive analytics capabilities enable operators to anticipate equipment failures and maintenance needs, allowing for proactive management and minimizing downtime.

The Emerson 3000 features a modular architecture, providing flexibility for scaling and customization. Operators can easily tailor the system to fit specific application needs, whether it requires additional control loops or integration with other systems. This adaptability is particularly beneficial for facilities planning for future expansions or modifications.

Another technology highlight of the Emerson 3000 is its seamless integration with the latest Internet of Things (IoT) advancements. The system is designed to communicate effectively with a variety of smart devices and sensors, harnessing data to create insightful analytics that drive operational excellence. This connectivity empowers businesses to leverage big data for improved decision-making and increased agility.

Additionally, the Emerson 3000 incorporates state-of-the-art cybersecurity measures to safeguard critical data and operations. With built-in security protocols and regular updates, the system protects against emerging cyber threats, ensuring the integrity of the control network.

User experience is also a focal point of the Emerson 3000. The intuitive graphical user interface presents complex data in a user-friendly format, making it easier for operators to monitor system performance and respond to alerts quickly. This ease of use contributes to enhanced safety and operational efficiency.

In summary, the Emerson 3000 represents a fusion of advanced process control, modular design, IoT connectivity, robust cybersecurity, and user-centric interface, making it an ideal choice for industries seeking to enhance their operational performance while adapting to ever-evolving technological landscapes.