Conair CMA-79 manual Assembling the rotating knives, Assembling the upper fixed knife

Page 13

CONAIR

MARTIN

Assembling the rotating knives

1.Clean the cutter's knife location and place a rotating knife there.

2.Screw in the fastening screws (C) with washers and gently tighten the screws. NOTE:Ê Check that the washers do not bear against the fixed knives.

3.Adjust the knife using the setting screws (B) until the correct amount of play,

0.20 - 0.30 mm, is obtained between the fixed and rotating knife. Using the feeler gauge inlcuded in the tool kit, check the amount of play.

4.When the correct amount of play has been obtained, tighten the screws (C) using a torque of 220 Nm.

5.Set the other rotating knives in place in the same

way. To turn the cutter easily, use the socket-head screw in the motor shaft.

Assembling the upper fixed knife

6.Push the upper fixed knife into its groove.

7.Turn the cutter so that the rotating knife's cutting edge is directly in front of the upper fixed knife's cutting edge.

8.Adjust the fixed knife using the setting screws (F) until the correct amount of play, 0.20 - 0.30 mm, is obtained.

9.Tighten the screws (E), 5 pcs, along the upper long side, and the two that were loosened on one short side.

10.To ensure that the knife's setting on the cutter does not change, turn the setting screws (B)Ê back 1/6 turn and hold in this position while tightening the locking nuts (A). Then tighten the locking nuts (E)Ê on the setting screws for the fixed knives.

13.Using a feeler gauge, check the distance between the fixed and rotating knives. The distance should not fall below 0.20 mm.

0 5 - 1 5 - 9 6

7 9

13

Image 13
Contents Manual Contents Introduction Dimensions Technical specificationsData Serial NumberOverview Functional descriptionSafety system = WARNING! Risk of being cut or caught in the machinery Safety regulationsPre-start checks InstallationTwo hours after first start Opening and closing the hopper and screenboxHopper Electrical connectionStarting and stopping Operation and daily maintenanceInspection Daily inspectionTrouble-shooting CleaningOr at least once every 300 hours If the granulator does not startChanging the knives ServicingChanging the fixed and rotating knives Assembling the upper fixed knife Assembling the rotating knivesOverview Sharpening the knivesSharpening the fixed and rotating knives Fixed knivesRotating knives Disassembling Disassembling/assembling the screwAssembling Lubrication Spare parts list 1a 79, Diagram Pos Qty 1b 79, Table2 79, Knives, fixed and rotating Electrical scheme Layout Options 11.1.1 79, Air-veyor Delay time interval T2 the time Pause/pulse relay when emptying with Air-veyorLevel control, capacitive Setting the sensitivityStoring Transporting and storing