Conair CMA-79 manual Cleaning, Trouble-shooting, Or at least once every 300 hours

Page 11

CONAIR

MARTIN

6.3Cleaning

NOTE: Set the main circuit-breaker to position "0" when cleaning the granulator. Empty the granulator of all material before re-starting.

Always take great care when handling the knives since they are very sharp and can cause personal injury.

1.Open the hopper and screenbox as described in chapter 5.2.

2.Clean the hopper, screen and granule bin.

3.Clean the cutter-housing and inside the stand.

4.Be sure to clean the groove (6) between the gear and cutter housing and remove any material which may get into the gear.

5.Replace all parts in reverse order.

Note: Steps 2 - 5 should be carried out every time the machine is cleaned,

or at least once every 300 hours.

6.4Trouble-shooting

6.4.1If the granulator does not start

Check that the saftey switches’ break loops are completely pushed in.

Check that the emergency stop is not activated. It can be reset by turning the button in the direction of the arrow.

The bimetal relay F1 in the electrical cabinet, according to the diagram opposite, is released if you press stop or overload the granulator. This is indicated by the small

green rectangular pin (P), which sticks up

above the surface of the bimetal relay. WhenP you reset by pressing the "Reset" button, the

pin (P)Ê is pushed back in so that it is level with the surface of the bimetal relay.

0 5 - 1 5 - 9 6

7 9

11

Image 11
Contents Manual Contents Introduction Serial Number Technical specificationsDimensions DataOverview Functional descriptionSafety system = WARNING! Risk of being cut or caught in the machinery Safety regulationsOpening and closing the hopper and screenbox InstallationPre-start checks Two hours after first startHopper Electrical connectionDaily inspection Operation and daily maintenanceStarting and stopping InspectionIf the granulator does not start CleaningTrouble-shooting Or at least once every 300 hoursChanging the fixed and rotating knives ServicingChanging the knives Assembling the upper fixed knife Assembling the rotating knivesFixed knives Sharpening the knivesOverview Sharpening the fixed and rotating knivesRotating knives Assembling Disassembling/assembling the screwDisassembling Lubrication Spare parts list 1a 79, Diagram Pos Qty 1b 79, Table2 79, Knives, fixed and rotating Electrical scheme Layout Options 11.1.1 79, Air-veyor Delay time interval T2 the time Pause/pulse relay when emptying with Air-veyorLevel control, capacitive Setting the sensitivityStoring Transporting and storing