Conair CMA-79 manual Safety regulations, = WARNING! Risk of being cut or caught in the machinery

Page 7

CONAIR

MARTIN

4.Safety regulations

4.1Overview

CONAIR MARTIN granulators are built for granulation of injection moulded, blow moulded or extruded plastic waste, which must not exceed the granulator's size and performance as described in chapter 2.

The granulator is equipped with safety switches to prevent the front door and the hopper from being opened during operation. The following safety measures should always be observed when handling the granulator:

WARNING! High Voltage! The electrical installation work must only be carried out by authorised personnel!

Always switch off the power supply using the main circuit-breaker (on top of the electrical cabinet) before opening the granulator. WARNING! High voltage remains on the incoming phase's connection block and up to the main circuit-breaker!

Never put any part of your body into any openings on the granulator unless the main circuit-breaker is in the "OFF" (=0) position.

Always be careful when the knives are in reach since they are very sharp. When the rotor has to be rotated manually, this must be done with the greatest care!

Be careful when the hopper and screenbox are opened and closed so that no part of your body gets caught.

The granulator cannot be started until the screenbox and the hopper are locked.

= WARNING! High Voltage!

This sign is placed on the electrical cabinet's door and any connection boxes.

= WARNING! Risk of being cut or caught in the machinery!

This sign is placed as necessary next to dangerous parts, for example the hopper and screenbox.

As long as the instructions in this manual are followed carefully, there should be no other dangers.

0 5 - 1 5 - 9 6

7 9

7

Image 7
Contents Manual Contents Introduction Serial Number Technical specificationsDimensions DataOverview Functional descriptionSafety system = WARNING! Risk of being cut or caught in the machinery Safety regulationsOpening and closing the hopper and screenbox InstallationPre-start checks Two hours after first startHopper Electrical connectionDaily inspection Operation and daily maintenanceStarting and stopping InspectionIf the granulator does not start CleaningTrouble-shooting Or at least once every 300 hoursChanging the knives ServicingChanging the fixed and rotating knives Assembling the upper fixed knife Assembling the rotating knivesFixed knives Sharpening the knivesOverview Sharpening the fixed and rotating knivesRotating knives Disassembling Disassembling/assembling the screwAssembling Lubrication Spare parts list 1a 79, Diagram Pos Qty 1b 79, Table2 79, Knives, fixed and rotating Electrical scheme Layout Options 11.1.1 79, Air-veyor Delay time interval T2 the time Pause/pulse relay when emptying with Air-veyorLevel control, capacitive Setting the sensitivityStoring Transporting and storing