3.2Safety system
Since there are rotating knives inside the granulator, there is a
Emergency stop: The equipment is fitted with an emergency stop switch on the control panel. The emergency stop is activated by pushing the button. It is reset by turning the button in the direction of the arrow
Safety switches: The safety system includes 2 safety switches. The switches are located as follows:
•1 by the hopper
•1 by the screenbox
The system is designed so that when the screenbox is pulled out a safety switch is actuated which cuts off the power so that the rotor and screw stop before the screenbox can be opened.
Similarly, for the hopper, a safety switch is actuated by a loop being pulled out of the switch and breaking the electric circuit when the locking clamp is pressed down and the inlet funnel or protective cover is released.