11.2 Console Tab
The Console tab displays fi
Subscriber Password
Enter a new
Provider Password
Enter a new
Mode After Disconnect
Select the mode the Console will assume after programming when the Console disconnects:
•Home — The Console will assume Home Mode after disconnect (default).
•Away — The Console will assume Away Mode after disconnect.
Transmission Supervision Interval
Supervised transmitters can send recurring status signals to the Console. This option sets the length of time required before the Console will recognize that a sensor’s status reports have not been received.
✓NOTE: This setting does not affect supervision timing for smoke and carbon monoxide detectors. These types of sensors are always set by the Console to require reception of a status signal at least once every 24 hours.
Select one of the six options for the supervision interval: 12 hours, 24 hours (default), 3, 7, 14, or 30 days. This setting effects all
✓NOTE FOR UL APPLICATIONS: UL requires the Transmitter Supervision Interval option to be set to 24 hours.
Emergency Siren
The Console contains an emergency siren that can sound for fi ve minutes when an emergency alarm is triggered, or until the report to the monitoring service is complete. The default for the siren is enabled. Optionally the siren can be disabled by
✓NOTE: This setting does not affect emergency alarms from smoke and carbon monoxide detectors. These types of sensors always trigger the emergency siren regardless of this setting.
Voice Prompts
The Console contains a voice synthesizer that can announce system alarms and status.The default for the voice prompts is enabled. Optionally, the voice prompts can be disabled by
RA4200 Console Tab