Linear PERS-4200 Series manual Sending and Receiving Console Data, Console Time and Date

Page 29

12.3 Sending and Receiving Console Data

Once the Console is connected to the RA4200 software, data can be exchanged in either direction.

Console Time and Date

The Console’s clock and calendar will maintain the current time & date.

IMPORTANT! THE CONSOLE’S TIME AND DATE MUST BE SET PRIORTO USE TO SUPPORT THE EVENT LOGGING AND REMINDER MESSAGE FEATURES.

NOTE: If the Console is using IP reporting, the Console’s data and time are automatically set by the cellular network.

If the Console’s clock or calendar needs setting or changing, use these steps.

1.Connect to the Console. The green CONNECTED indicator will display at the bottom of the RA4200 window.

2.Press CONSOLE TIME. The SetTime window will display.

3.To check a Console’s clock and calendar, press GET TIME. The current settings will be displayed in the SetTime window.

OR —

4.Enter the new time and date. If daylight saving time is enabled, verify the start and stop dates. Press SET TIME to update the Console’s date and time.

5.Press DONE to close the SetTime window.

First Time Programming for New Consoles

When a Console is new or un-programmed it will announce:

0“Console not ready... please configure before use”

The Console must be programmed with an account number, a Central Station phone number and a corresponding PSTN or IP reporting format. If one or more of these required parameters is missing the Console will not operate.

Use the following steps when programming a new Console:

1.Open the Account Template created for the specifi c subscriber and Console installation.

2.Connect to the Console. The green CONNECTED indicator will display at the bottom of the RA4200 window.

3.Press CONSOLE TIME. The SetTime window will display. If not correct, enter the correct time and date. If daylight saving time is enabled, verify the start and stop dates. Press SET TIME to update the Console’s date and time. Press DONE.

4.Press SET CONSOLE. The template will be sent to the Console.

5.Press DISCONNECT to disconnect from the Console. The red NOT CONNECTED indicator will display at the bottom of the RA4200 window.

Existing Console Programming

Connecting to a Console with existing programming can be managed two ways:

Method 1: Make the changes to an Account Template off-line fi rst, before connecting to the Console, then connect to the Console and send it the template.

Method 2: Open an Account Template, connect to the Console, then retrieve the data from the Console into the template.

The fi rst method is preferred when all programming for a Console has been made (and is being stored) by the RA4200 software. This method will keep all the PERS provider’s Consoles synchronized with the RA4200 Account Template fi les.

The second method is useful if programming changes have been made to a Console through remote touch-tone telephone programming. Those changes can be retrieved into an Account Template, updating the template. Be sure to save the template after updating it.

Use the following steps when programming an existing Console:

1.Open the Account Template created for the specifi c subscriber and Console installation. (When using Method 1, make any changes required.)

2.Connect to the Console. The green CONNECTED indicator will display at the bottom of the RA4200 window.

3.Method 1 - Press SET CONSOLE. The template will be sent to the Console.

OR —

4.Method 2 - Press GET CONSOLE. The Console’s data will be sent to the template. Press SAVE and select an Account Template fi le name.

NOTE: The data in the open template will be overwritten with the data from the Console.

5.Press DISCONNECT to disconnect from the Console. The red NOT CONNECTED indicator will display at the bottom of the RA4200 window.

27

Image 29
Contents PERS-4200 Series Important Pers Installation Warnings Contents Product Description Power SupplyVoice Prompts ProgrammingEmergency Operation SummaryActivity FireHome Button Cover Remote Speaker/Microphone ModuleAlternate Console Labels Power Supply Installation Option Module InstallationConsole Connections Telephone ConnectionsProvider Modes Console Modes & FeaturesProvider Features User Modes User FeaturesPower Off Mode Using the Provider ModesNot-Ready Mode Programming ModeSoftware Description Programming with RA4200System Requirements RA4200 can connect to the Console two waysProgramming Outline RA4200 Software InstallationCommand and Response modem information. If the modem is not Testing the ModemWorking properly, Windows will notify you To Test the Modem in Windows XPAccount Template Tabs 10. RA4200 Software OverviewDrop-down Menu Items and Icons Sub-menus that can be accessed from the Menu Bar areMenu Bar Customer Tab Console Tab Console Time Settings Temperature Limit SettingsAnnunciate Trouble Indication Annunciate Status with Home ButtonSensors Tab Low Battery Report OptionsSensor types selections available are Sensor Status IndicatorsSensor Zones Pstn Dialing Sequence Communicator TabCommunicator Fallback Enter the account number for the specifi c Console Internet Protocol IP ReportingThree Central Station Pstn reporting formats are available Three Central Station IP reporting formats are availableReporting Options Tab Mode Switch ReportingReport AC Fail Report Supervisory EventsTwo-way Audio Mode Speaker Phone Timer2 Alarm Codes Automatic Status ReportsAudio Replay During Timeout Reminder SettingsReminder Messages Tab Report Missed ReminderFour types of reminder messages are available Reminder Time Slot SettingsChoose a reminder message type Test ReminderCreating or Editing Reminder Messages Send/Receive Window Console CommunicationSending and Receiving Console Data When a Console is new or un-programmed it will announceConsole Time and Date First Time Programming for New ConsolesLimited Remote Telephone Programming Connecting with the ConsoleOption 1 Reporting Format Option 2 Primary Telephone NumberLearning Sensors Sensor Learn / Test ModeActivate the sensor to learn. The Console will announce Console will announce the next available zone numberErasing All Sensors Testing SensorsLearning a Single Sensor Retrieving the Event Log Event LogPrinting the Event Log Clearing the Event LogPrinting or Exporting a Template Updating Console Firmware System Firmware Update Utility InstructionsFirmware Update Utility Instructions Upgrade Complete Reporting Code CID Appendix a Reporting CodesSystem Event Appendix B Mode TableOpening Port COM30 Appendix C Communications Status Window TableSpecifications Power RequirementsRegulatory Information Linear Limited Warranty#’s IndexSIM ID Copyright 2014 Linear LLC 237016 a