Linear PERS-4200 Series manual Internet Protocol IP Reporting

Page 22

Public Switched Telephone Network (PSTN) Reporting

Settings for dial-up reporting using the telephone network are set in this area.

Account Number

The account number can be up to 10 digits long. The last four digits of the account number will be used as the communicator’s account number for 4x2 and CID format reports to the monitoring service.

IMPORTANT! THE ACCOUNT NUMBER FIELD IS REQUIRED.

SurGard System III - compatible SIA requires a 10-digit number

PSTN/SIA requires a 6-digit number

PSTN/CID and 4 by 2 requires a 4-digit number.

Enter the account number for the specifi c Console.

Reporting Format

Three Central Station PSTN reporting formats are available.

Contact ID (CID)

SIA

4 by 2

Contact ID is the default format. Select one of the other formats as required by the Central Station.

Dialing Format

The default dialing format is DTMF tone dialing. If the telephone system that the Console will be connected to does not support DTMF tone dialing, select pulse dialing.

Dialing Tones Audible

By default dialing tones do not sound from the Console’s speaker. This option is typically used for troubleshooting telephone issues.

Check this option box to have the Console speaker active during dialing.

Primary Telephone Number

The primary telephone number is the number that will be dialed fi rst in the dialing sequence. The number can be up to 20 digits including commas that each add a one second pause.

IMPORTANT!THE PRIMARYTELEPHONE NUMBER FIELD IS REQUIRED.

Secondary Telephone Number

The secondary telephone number is the number that will be dialed second in the dialing sequence if the primary number is unsuccessful. The number can be up to 20 digits including commas that each add a one second pause.

Split Reporting

The Console can report supervisory events to a supervisory telephone number if split reporting is enabled. Split reporting is disabled by default.

When split reporting is enabled, reports for alarm events, reminder message timeouts, activity window expirations, and 2-way audio calls are made to the primary and secondary phone numbers.

Reports of home/away mode, Console trouble conditions, sensor trouble conditions, and Automatic Status reports are made separately to the supervisory phone number only.

Supervisory Telephone Number

The supervisory telephone number is the number that will be dialed to report supervisory events if split reporting is enabled. The number can be up to 20 digits including commas that each add a one second pause.

Internet Protocol (IP) Reporting

The PERS-4200 Console can be configured to communicate over-the-air (OTA) using the optional add-on Model UMTS-3G Cellular Module. The Module supports over-the-air data reporting for the PERS Console using 3G and voice communications through the carrier’s cellular telephone network.

The settings for IP reporting using the cellular module are set in this area.

IP Account Number

The FIBRO IP reporting protocol allows up to 10 digits in the account number. PERS truncates the left-most digits of the account number to fi t the reporting format used. The cellular module adds left-most zeroes as necessary for IP reporting. Enter the account number used for SurGard IP reporting for the specifi c Console.

DNIS / Line #

DNIS is used by the Central station to help identify accounts. This allows there to be multiple panels sending SIA/Contact ID events using account 1234 for example. The DNIS may be transmitted to the automation software/printer to ID account 1234 as belonging to dealer X (DNIS 00001) and the other account 1234 as belong to dealer Y (DNIS of

00002). If it is not used it should be sent as all 0’s and it will not allow the SIA/Contact ID account numbers to be extended.

FIBRO Heartbeat

Enter the time (in seconds) required by the Central Station receiver for the FIBRO heartbeat. Default is 7200 seconds.

Linear Voice Gateway Management Timer

Enter the time (in minutes) for the periodic management connection to the voice gateway, used for over-the-air confi guration update and fi rmware download.

SIM ID

Displays the Subscriber Identity Module ID being used in the cellular module.

Central Station IP Address

The area is for entering the Central Station’s primary and secondary IP address’, local port, and remote port numbers for the server that will be receiving alarm reports from the Console. Enter the values required by the server.

Voice Gateway

The area is for entering the Central Station’s voice gateway IP address for the Linear Voice Gateway that will be handling voice-over-IP (VOIP) communications from the Console during 2-way audio mode. Refer to the Linear Voice Gateway instructions and settings for details.

IP Reporting Format

Three Central Station IP reporting formats are available.

Surgard System III-compatible SIA

Surgard System III-compatible CID18 Extended

Surgard System III-compatible CID58 Extended

SURGARD SYSTEM III-COMPATIBLE CID18 EXTENDED is the default format. Select one of the other formats if required by the Central Station.

Cellular Network ID

Used to connect to a specifi c network. This specifi es the numeric network identifi er, which is made from the Mobile Country Code (MCC) and Mobile Network Code (MNC).

IP Service

The cellular service data network name string. For example: wap.cingular or m2m.com.attz.

LEMI Ports

This area displays the name and fi rmware revision number of any option modules connected to the Console.

20

Image 22
Contents PERS-4200 Series Important Pers Installation Warnings Contents Voice Prompts Power SupplyProduct Description ProgrammingActivity Operation SummaryEmergency FireAlternate Console Labels Remote Speaker/Microphone ModuleHome Button Cover Console Connections Option Module InstallationPower Supply Installation Telephone ConnectionsProvider Features Console Modes & FeaturesProvider Modes User Features User ModesNot-Ready Mode Using the Provider ModesPower Off Mode Programming ModeSystem Requirements Programming with RA4200Software Description RA4200 can connect to the Console two waysRA4200 Software Installation Programming OutlineWorking properly, Windows will notify you Testing the ModemCommand and Response modem information. If the modem is not To Test the Modem in Windows XP10. RA4200 Software Overview Account Template TabsMenu Bar Sub-menus that can be accessed from the Menu Bar areDrop-down Menu Items and Icons Customer Tab Console Tab Annunciate Trouble Indication Temperature Limit SettingsConsole Time Settings Annunciate Status with Home ButtonLow Battery Report Options Sensors TabSensor Zones Sensor Status IndicatorsSensor types selections available are Communicator Fallback Communicator TabPstn Dialing Sequence Three Central Station Pstn reporting formats are available Internet Protocol IP ReportingEnter the account number for the specifi c Console Three Central Station IP reporting formats are availableReport AC Fail Mode Switch ReportingReporting Options Tab Report Supervisory Events2 Alarm Codes Speaker Phone TimerTwo-way Audio Mode Automatic Status ReportsReminder Messages Tab Reminder SettingsAudio Replay During Timeout Report Missed ReminderReminder Time Slot Settings Four types of reminder messages are availableCreating or Editing Reminder Messages Test ReminderChoose a reminder message type Console Communication Send/Receive WindowConsole Time and Date When a Console is new or un-programmed it will announceSending and Receiving Console Data First Time Programming for New ConsolesOption 1 Reporting Format Connecting with the ConsoleLimited Remote Telephone Programming Option 2 Primary Telephone NumberActivate the sensor to learn. The Console will announce Sensor Learn / Test ModeLearning Sensors Console will announce the next available zone numberLearning a Single Sensor Testing SensorsErasing All Sensors Printing the Event Log Event LogRetrieving the Event Log Clearing the Event LogPrinting or Exporting a Template Firmware Update Utility Instructions System Firmware Update Utility InstructionsUpdating Console Firmware Upgrade Complete Appendix a Reporting Codes Reporting Code CIDAppendix B Mode Table System EventAppendix C Communications Status Window Table Opening Port COM30Power Requirements SpecificationsLinear Limited Warranty Regulatory InformationIndex #’sSIM ID Copyright 2014 Linear LLC 237016 a