2.2Console Options Cellular Interface Module

The Model UMTS-3G Cellular Interface Module provides 2-way over-the-air digital communications between the Console and the monitoring service. The cellular module can be used to replace the traditional land-line telephone connection for emergency reporting.

Remote Speaker/Microphone Module

The Model RSM-MODULE Remote Speaker/Microphone Module extends the usable range for 2-way audio communications with the monitoring service. The plug-in module and its remote speaker/microphone unit allow the monitoring service to talk and listen to the subscriber from an additional location in the installation that is remote from the Console.

Alternate Console Labels

For customizing the Console, an alternate set of button identifi cation labels are provided. The labels describe the Console’s buttons in French, or Spanish language, or in Braille characters. Apply the label required to the Console, above the buttons.

HOME Button Cover

For installations where the activity timer will not be used, a snap-on button cover is supplied to hide the HOME button.

NOTE: The HOME button cover cannot be easily removed once the cover is in place.

OPTION MODULES PLUG INTO CONSOLE

CELLULAR

 

TELEPHONE

REMOTE

MODULE

 

SPEAKER/MICROPHONE

 

MODULE

PERS-4200 Plug-in Option Modules

IF REQUIRED, APPLY BRAILLE,

FRENCH, OR SPANISH

LABEL TO CONSOLE

TO HIDE THE HOME BUTTON IF THE

ACTIVITY TIMER IS NOT GOING TO BE

USED, SNAP THE HOME BUTTON

COVER INTO THE CONSOLE

TIP: INSTALL THE BUTTON COVER

BY PRESSING THE SLOT EDGE IN

FIRST, THEN SNAP THE TOP EDGE

OF THE COVER DOWN

NOTCH IN THE BUTTON COVER LINES UP

WITH NOTCH IN THE CONSOLE CASE

Alternate Console Labels and HOME Button Cover

 

 

 

ANTENNA

 

 

CONSOLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REAR

 

OPTION

 

 

 

BATTERY

 

 

 

MODULE

 

 

 

DOOR

 

 

SPEAKER

 

 

 

 

LINE IN

 

REMOTE

 

 

 

 

 

SPEAKER / MICROPHONE

 

 

 

 

 

JACK

 

 

 

 

 

 

 

MODULE SOCKET

 

 

 

CONSOLE

 

 

 

 

 

 

 

 

 

 

 

FRONT

PHONE OUT

USB

CELLULAR TELEPHONE

 

 

 

 

 

JACK PROGRAMMING

MODULE SOCKET

 

 

 

 

 

 

JACK

POWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SUPPLY

HOME

 

TEMPERATURE

2-WAY

 

 

 

BUTTON

 

 

 

 

HELP

SENSOR

AUDIO

 

 

 

CANCEL

 

 

 

 

 

VOLUME

 

 

BUTTON

BUTTON

 

 

 

 

TEST

MICROPHONE

 

SPEAKER

 

 

BUTTON

 

 

 

 

 

 

NOTE FOR UL APPLICATIONS:

VOLUME

 

 

 

 

 

 

 

CONSOLE

SPEAKER VOLUME MUST BE

 

POWER OFF

 

BOTTOM

SET SO ANNOUNCEMENTS CAN

 

BUTTON

 

 

 

BE HEARD FROM ACROSS THE ROOM

 

 

 

 

PERS-4200 Console Component Locations

4

Image 6
Contents PERS-4200 Series Important Pers Installation Warnings Contents Voice Prompts Power SupplyProduct Description ProgrammingActivity Operation SummaryEmergency FireRemote Speaker/Microphone Module Alternate Console LabelsHome Button Cover Console Connections Option Module InstallationPower Supply Installation Telephone ConnectionsConsole Modes & Features Provider FeaturesProvider Modes User Features User ModesNot-Ready Mode Using the Provider ModesPower Off Mode Programming ModeSystem Requirements Programming with RA4200Software Description RA4200 can connect to the Console two waysRA4200 Software Installation Programming OutlineWorking properly, Windows will notify you Testing the ModemCommand and Response modem information. If the modem is not To Test the Modem in Windows XP10. RA4200 Software Overview Account Template TabsSub-menus that can be accessed from the Menu Bar are Menu BarDrop-down Menu Items and Icons Customer Tab Console Tab Annunciate Trouble Indication Temperature Limit SettingsConsole Time Settings Annunciate Status with Home ButtonLow Battery Report Options Sensors TabSensor Status Indicators Sensor ZonesSensor types selections available are Communicator Tab Communicator FallbackPstn Dialing Sequence Three Central Station Pstn reporting formats are available Internet Protocol IP ReportingEnter the account number for the specifi c Console Three Central Station IP reporting formats are availableReport AC Fail Mode Switch ReportingReporting Options Tab Report Supervisory Events2 Alarm Codes Speaker Phone TimerTwo-way Audio Mode Automatic Status ReportsReminder Messages Tab Reminder SettingsAudio Replay During Timeout Report Missed ReminderReminder Time Slot Settings Four types of reminder messages are availableTest Reminder Creating or Editing Reminder MessagesChoose a reminder message type Console Communication Send/Receive WindowConsole Time and Date When a Console is new or un-programmed it will announceSending and Receiving Console Data First Time Programming for New ConsolesOption 1 Reporting Format Connecting with the ConsoleLimited Remote Telephone Programming Option 2 Primary Telephone NumberActivate the sensor to learn. The Console will announce Sensor Learn / Test ModeLearning Sensors Console will announce the next available zone numberTesting Sensors Learning a Single SensorErasing All Sensors Printing the Event Log Event LogRetrieving the Event Log Clearing the Event LogPrinting or Exporting a Template System Firmware Update Utility Instructions Firmware Update Utility InstructionsUpdating Console Firmware Upgrade Complete Appendix a Reporting Codes Reporting Code CIDAppendix B Mode Table System EventAppendix C Communications Status Window Table Opening Port COM30Power Requirements SpecificationsLinear Limited Warranty Regulatory InformationIndex #’sSIM ID Copyright 2014 Linear LLC 237016 a