18. Appendix B - Mode Table
SYSTEM EVENT
Fire & CO Alarms
Fire & CO Supervisory Timeout [2]
Fire & CO Sensor Low
Battery [2]
Console (HELP button) Alarm
Emergency Sensor Alarm
Emergency Sensor Supervisory Timeout [2]
Emergency Sensor Low
Battery [2]
Console Trouble [2] & [5]
Communication Status (telephone/cell)
Module Status
Activity Monitor
Temperature Alarms
Missed Reminder Messages
Entering Mode
CONSOLE OPERATING MODE
| HOME MODE |
|
| AWAY MODE |
|
| NIGHT MODE |
| |
|
| (Overrides Night Mode) |
|
| |||||
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| |
Reports to Central Station | Voice Announcement | Starts | Reports to Central Station | Voice Announcement | Starts | Reports to Central Station | Voice Announcement | Starts | |
✓ Yes | ✓ Yes | ~ If Enabled [6] | ✓ Yes | ✓ Yes | ~ If Enabled [6] | ✓ Yes | ✓ Yes | ~ If Enabled [6] | |
✓ Yes | ~ If Enabled [8] | N/A | ✓ Yes | ✗ No | N/A | ✓ Yes | ✗ No | N/A | |
✓ Yes | ~ If Enabled [8] | N/A | ✓ Yes | ✗ No | N/A | ✓ Yes | ✗ No | N/A | |
✓ Yes | ✓ Yes | ~ If Enabled | ✓ Yes | ✓ Yes | ~ If Enabled | ✓ Yes | ✓ Yes | ~ If Enabled | |
✓ Yes | ✓ Yes | ~ If Enabled [6] | ✓ Yes | ✓ Yes | ~ If Enabled [6] | ✓ Yes | ✓ Yes | ~ If Enabled [6] | |
~ If Enabled | ~ If Enabled [8] | N/A | ✗ No [1] | ✗ No [1] | N/A | ~ If Enabled | ✗ No | ✗ No | |
✓ Yes | ~ If Enabled [8] |
| ✓ Yes | ✗ No [1] |
| ✓ Yes | ✗ No |
| |
N/A | N/A | N/A | |||||||
✓ Yes | ~ If Enabled |
| ✓ Yes | ✗ No |
| ✓ Yes | ✗ No |
| |
N/A | N/A | N/A | |||||||
[8] & [9] | |||||||||
|
|
|
|
|
|
|
| ||
✗ No | ✓ Yes | N/A | ✗ No | ✓ Yes | N/A | ✗ No | ✗ No | N/A | |
| ✓ Yes |
|
| ✗ No |
|
| ✗ No |
| |
N/A | N/A | N/A | N/A | N/A | N/A | ||||
✓ Yes | ✓ Yes | ~ If Enabled [7] | ✗ No | ✗ No | ✗ No | ✓ Yes | ✓ Yes | ~ If Enabled [7] | |
~ If Enabled [4] | ~ If Enabled [4] | ~ If Enabled [4] | ~ If Enabled [3] | ~ If Enabled [3] | ~ If Enabled [3] | ~ If Enabled [3] | ~ If Enabled [3] | ~ If Enabled [3] | |
✓ Yes [11] | ✓ Yes | ~ If Enabled | ✗ No | ✗ No | ✗ No | ✓ Yes [11] | ✓ Yes | ~ If Enabled | |
✓ Yes | From Away | N/A | ✓ Yes | ✓ Yes | N/A | From Away | From Away | N/A | |
Mode Only [10] | Mode Only | Mode Only | |||||||
|
|
|
|
|
|
Mode Table Notes:
•[1] Setting the Console in Away Mode clears all supervisory events for emergency sensors only. Supervisory timers for Smoke detectors, CO detectors, and activity monitor sensors are not affected; switching to Home or Away Mode constitutes activity.
•[2] Supervisory events are reported by automatic status reports regardless of the global REPORT SUPERVISORY EVENTS setting. Also, AC power loss events are reported by automatic status reports regardless of the global REPORT AC FAIL setting. Both settings are on the Reporting Options tab.
•[3] If ENABLE HOME MODE ONLY is selected for TEMPERATURE LIMIT SETTINGS on the Console tab, temperature alarms will not occur in this mode. Select ENABLE to allow temperature alarms in this mode.
•[4] Either ENABLE or ENABLE HOME MODE ONLY needs to be selected on the Console tab for TEMPERATURE LIMIT SETTINGS to allow temperature alarms.
•[5] Console supervisory faults are always reported, but not annunciated in Away Mode and Night Mode.
•[6] To start a
•[7] For activity sensors,
•[8] To enable Console/sensor zone low battery and sensor zone supervision annunciations, ANNUNCIATE TROUBLE INDICATION must be selected on the Console tab.
•[9] To announce telephone line and AC power status, ANNUNCIATE
•[10] The Console will only announce Home Mode when manually switched from Away Mode using the HOME button.
•[11] To report missed reminder messages, the global REPORT MISSED REMINDER option must be selected on the Reminder Messages tab and the reminder message slot must have the SEND REPORT option selected.
36