Phonetics 1104 user manual Now press Pause once to activate a four second delay. This

Page 43

Chapter 4: Communications Programming

6. Now press PAUSE once to activate a four second delay. This

assumes the call is answered by a beeper/pager service that

immediately delivers a prerecorded voice message. PAUSE

may be pressed more than once to program more time for the

beeper/pager service to finish its message. Each press of

PAUSE allocates four additional seconds. The Model 1104

will “beep” with each press.

RING/TAD

PAUSE

AM

7. Enter a telephone number or custom code number that will

identify the Model 1104 as the caller to your beeper or pager.

A code may consist of any number(s) you designate. Many

users find it convenient to use the telephone number to which

the Model 1104 is connected.

1

CALL

DELAY

4

MAX CALLS

7

RECOGNITION

TIME

2

VOICE

REPS

5

TEMP LIMITS

8

CLOCK

0

ID NUMBER

POWER

3

INTERCALL

TIME

6

CALIBRATE

9

LISTEN TIME

SOUND

8.A pound or asterisk may be required in some dialing situations. If required, position the pound (#) or asterisk (*) within the telephone number where required by pressing SET (where the pound is located) or WHAT IS (where the asterisk is located). The Model 1104 will “beep” each time pound or asterisk is pressed. Enter any remaining digits of the telephone number.

SET

#

–OR–

WHAT

IS

*

9.Press ENTER. The Model 1104 will say “Enter.”

ENTER

TONE

PM

43

Image 43
Contents Model SENSAPHONE, INC Important Safety Instructions Sensaphone Model 1104 User’s Manual PHONETICS, INC FCC RequirementsSensaphone Model 1104 User’s Manual Canadian Department of Communications Statement Sensaphone Model 1104 User’s Manual Viii Technical Support Summary of the Alarm Dial-Out ProcessRings Until Answer Unit ID NumberDial-out Telephone Numbers Tone or Pulse Dialing Special DialingTemperature Scale Input ConfigurationEnable/Disable Inputs Establishing High and Low Temperature LimitsStatus Report High Sound Alarm Enable/DisableExit Delay Alarm AcknowledgmentIntroduction Technical Support Operating Environment Installation+ + + RUN Installing the Telephone Line Alert Inputs Sensor Connected to an Alert Input Two Sensors Wired to Adjacent Inputs ~ ~ From the unit completely to avoid damage to the circuitry Disconnecting the Model 1104 for Storage or Seasonal UseSensaphone Model 1104 User’s Manual Local Keypad Quick StartRUN Set Configuration of InputsSet the ID Number StatusNumber Set Dial-Out Telephone NumbersModel 1104 responds Enter low temperature limit Set Temperature LimitsModel 1104 responds Enter high temperature limit Quick Start Alert Condition Action-Response Programmable FeatureProgramming the ID Number Communications ProgrammingHello, this is telephone number Unit ID Number Interrogating the ID Number Enter number Programming Dial-out Telephone NumbersErasing a Telephone Number Interrogating a Dial-out Telephone NumberPress ENTER. The Model 1104 will say Enter Special Dialing Keys Tone or Pulse DialingPause Code Incorporating a PausePound # AsteriskPressed Incorporating a Pound # or AsteriskPress any unassigned number key from 1 to 4 to represent Special Dialing to a Beeper or Pager Now press Pause once to activate a four second delay. This Interrogating Rings Until Answer Programming Rings Until AnswerUsing the TAD Feature TAD Enable/DisableNo TAD In Use Programming the Listen-in Time Interrogating the Listen-in Time Programming the Call Delay Call DelayInterrogating Call Delay Local Voice Mute Enable/Disable Local Voice Mute10.2 Interrogating Voice Repetitions Programming Voice RepetitionsModel 1104 will recite the number programmed Programming Intercall Time Seconds Interrogating Intercall TimeProgramming Max Calls Interrogating Max Calls Setting the Clock Interrogating for the Current Time Unlocking the Keypad Locking the KeypadUsing the number keys, enter the digits for the code Sensaphone Model 1104 User’s Manual Alarm Programming Status Programming Input ConfigurationChanging Enabled/Disabled Input Status Verifying Input ConfigurationVerifying Enabled/Disabled Input Status Immediately follows the number recited for that input Programming Input Recognition TimeRecites the digits as they are pressed Interrogating Input Recognition TimePress the corresponding input key 1 to Programming Temperature Limits for a Selected Input Interrogating High and Low Temperature Limits Disabling Alarm Response to High or Low TemperatureTemperature Calibration Interrogating Temperature Calibration Programming Temperature CalibrationObtaining Current Temperature Enabling/Disabling the AC Power Alarm Model 1104 will recite the digits as they are pressed Programming Power Failure Recognition TimeInterrogating Power Failure Recognition Time Using the number keys, enter a value for sound sensitivity Programming Sound Alarm SensitivityInterrogating Sound Sensitivity Programming High Sound Alarm Recognition TimeChanging Enabled/Disabled High Sound Alarm Exit Delay Local Acknowledgment Acknowledgment Status Report & Remote AccessTouch-Tone Acknowledgment Callback Acknowledgment Example Status Report, No Alarms Example Status Report, Existing Alarms Battery Condition Example Status Report, Disabled InputsBattery Condition OK, if over 8.2 Volts Remote Access by Touch-Tone TelephoneReplace batteries, if below 7.2 Volts Activating Status Report Sensaphone Model 1104 User’s Manual Operation Alarm Detection, Dial-out and AcknowledgmentAlarm Message TemperatureValid Alarm Call DelayCall Progress Alarm MessagesIntercall Time Voice RepetitionsFast Code Local, On-siteAcknowledgment Touch-ToneNumber...the last number it dialed TAD EnabledHave a good day Example a Dial-out Telephone Call Appendix a Troubleshooting Cause ProblemSolution Communications / Dial-outAppendix a Troubleshooting Communications / Dial-out Problem Cause Solution Temperature Monitoring Problem Cause Solution Other Monitoring Problem Cause Solution Sound Level Monitoring Problem Cause Solution101 Appendix a Troubleshooting Use rechargeable nicad batteries Be sure to use alkaline batteries-do notAppendix B Weekly Testing Procedure 104 Part Number Sensor / Switch Appendix C AccessoriesSensaphone Model 1104 User’s Manual 106 Appendix D Returning the Unit for Repair Service DepartmentYear Limited Warranty