Phonetics 1104 user manual Enable/Disable Local Voice Mute

Page 51

Chapter 4: Communications Programming

4.9 Local Voice Mute

When the Model 1104 dials out to report an alarm, it also audibly recites the alarm message at its installation site. The Local Voice Mute command allows you to turn off the voice at the Model 1104’s site during alarm dialouts and status call-ins. This feature is used to prevent intruders or unauthorized persons from hearing the alarm dial-out message or from hearing the Status Report during an off-site call.

4.9.1 Enable/Disable Local Voice Mute

To enable/disable Local Voice Mute:

1.Press SENSOR ON/OFF.

SENSOR

ON/OFF

2.Press MUTE.

CODE

MUTE

The Model 1104 will say “On” to indicate that Local Voice Mute is enabled, or “Off” to indicate that it is disabled.

3.Repeat key sequence to switch between enabled or disabled Local Voice Mute.

51

Image 51
Contents Model SENSAPHONE, INC Important Safety Instructions Sensaphone Model 1104 User’s Manual PHONETICS, INC FCC RequirementsSensaphone Model 1104 User’s Manual Canadian Department of Communications Statement Sensaphone Model 1104 User’s Manual Viii Technical Support Summary of the Alarm Dial-Out ProcessRings Until Answer Unit ID NumberDial-out Telephone Numbers Tone or Pulse Dialing Special DialingTemperature Scale Input ConfigurationEnable/Disable Inputs Establishing High and Low Temperature LimitsStatus Report High Sound Alarm Enable/DisableExit Delay Alarm AcknowledgmentIntroduction Technical Support Operating Environment Installation+ + + RUN Installing the Telephone Line Alert Inputs Sensor Connected to an Alert Input Two Sensors Wired to Adjacent Inputs ~ ~ From the unit completely to avoid damage to the circuitry Disconnecting the Model 1104 for Storage or Seasonal UseSensaphone Model 1104 User’s Manual Local Keypad Quick StartRUN Set Configuration of InputsSet the ID Number StatusNumber Set Dial-Out Telephone NumbersModel 1104 responds Enter low temperature limit Set Temperature LimitsModel 1104 responds Enter high temperature limit Quick Start Alert Condition Action-Response Programmable FeatureCommunications Programming Programming the ID NumberHello, this is telephone number Unit ID Number Interrogating the ID Number Enter number Programming Dial-out Telephone NumbersErasing a Telephone Number Interrogating a Dial-out Telephone NumberPress ENTER. The Model 1104 will say Enter Tone or Pulse Dialing Special Dialing KeysPause Code Incorporating a PausePound # AsteriskPressed Incorporating a Pound # or AsteriskPress any unassigned number key from 1 to 4 to represent Special Dialing to a Beeper or Pager Now press Pause once to activate a four second delay. This Interrogating Rings Until Answer Programming Rings Until AnswerUsing the TAD Feature TAD Enable/DisableNo TAD In Use Programming the Listen-in Time Interrogating the Listen-in Time Programming the Call Delay Call DelayInterrogating Call Delay Local Voice Mute Enable/Disable Local Voice Mute10.2 Interrogating Voice Repetitions Programming Voice RepetitionsModel 1104 will recite the number programmed Programming Intercall Time Seconds Interrogating Intercall TimeProgramming Max Calls Interrogating Max Calls Setting the Clock Interrogating for the Current Time Unlocking the Keypad Locking the KeypadUsing the number keys, enter the digits for the code Sensaphone Model 1104 User’s Manual Alarm Programming Status Programming Input ConfigurationVerifying Input Configuration Changing Enabled/Disabled Input StatusVerifying Enabled/Disabled Input Status Immediately follows the number recited for that input Programming Input Recognition TimeRecites the digits as they are pressed Interrogating Input Recognition TimePress the corresponding input key 1 to Programming Temperature Limits for a Selected Input Interrogating High and Low Temperature Limits Disabling Alarm Response to High or Low TemperatureTemperature Calibration Interrogating Temperature Calibration Programming Temperature CalibrationObtaining Current Temperature Enabling/Disabling the AC Power Alarm Model 1104 will recite the digits as they are pressed Programming Power Failure Recognition TimeInterrogating Power Failure Recognition Time Using the number keys, enter a value for sound sensitivity Programming Sound Alarm SensitivityInterrogating Sound Sensitivity Programming High Sound Alarm Recognition TimeChanging Enabled/Disabled High Sound Alarm Exit Delay Acknowledgment Status Report & Remote Access Local AcknowledgmentTouch-Tone Acknowledgment Callback Acknowledgment Example Status Report, No Alarms Example Status Report, Existing Alarms Battery Condition Example Status Report, Disabled InputsRemote Access by Touch-Tone Telephone Battery Condition OK, if over 8.2 VoltsReplace batteries, if below 7.2 Volts Activating Status Report Sensaphone Model 1104 User’s Manual Operation Alarm Detection, Dial-out and AcknowledgmentAlarm Message TemperatureValid Alarm Call DelayCall Progress Alarm MessagesIntercall Time Voice RepetitionsFast Code Local, On-siteAcknowledgment Touch-ToneTAD Enabled Number...the last number it dialedHave a good day Example a Dial-out Telephone Call Appendix a Troubleshooting Cause ProblemSolution Communications / Dial-outAppendix a Troubleshooting Communications / Dial-out Problem Cause Solution Temperature Monitoring Problem Cause Solution Other Monitoring Problem Cause Solution Sound Level Monitoring Problem Cause Solution101 Appendix a Troubleshooting Use rechargeable nicad batteries Be sure to use alkaline batteries-do notAppendix B Weekly Testing Procedure 104 Part Number Sensor / Switch Appendix C AccessoriesSensaphone Model 1104 User’s Manual 106 Appendix D Returning the Unit for Repair Service DepartmentYear Limited Warranty