Recall Timer
Duration
Code: #107
Description: Changes the length of the timed signal (a switchhook flash) exe- cuted by the Recall feature (p.
Change the factory setting of the recall timer only under three conditions:
■If your PARTNER Plus system is connected to Centrex, set the recall timer to 800 milliseconds (msec) by entering [ 3 ] [ 2 ].
■If your PARTNER Plus system is connected to a PBX or Centrex and Recall drops calls, shorten the time.
■If pressing Recall has no effect, lengthen the time.
Valid Entries: 01 through 80 (25 to 2000 msec in 25 msec increments)
✓18 (450 msec)
Programming Steps:
1.Press [ Feature ] [ 0 ] [ 0 ] [ System Program ] [ System Program ] [ # ] [ 1 ] [ 0 ] [ 7 ] . The display reads:
Recall Timer
18
2.Enter a different recall timer setting by pressing [ Next Data ] or [ Prev Data ]. For example, to shorten the recaIl timer to 400 msec, press [ Prev Data ] twice.
The display reads:
Recall Timer
16
Or enter the setting number directly. For example, to set the recall timer to 800 msec, press [ 3 ] [ 2 ].
3.If you are using Recall to access PBX or Centrex features, test the new Recall Timer Duration by trying to use these features:
■If the call is disconnected, shorten the time.
■If the Recall signal has no effect, lengthen the time.
✓ = Factory Setting
| To go to the next procedure: [Next Proc ] | To go to a specific procedure: [# ] [ x ] [ x ] [ x ] [ x ] | ||
| ||||
|
|
|
| (where XX X is the procedure number) |
| To go to the previous procedure: [ Prev Proc ] | |||
|
| |||
| To return data to the factory setting: Remove[ | ] To exit system programming: [ Feature ] [ 0 ] [ 0 ] |
System Programming