3.1.4 Talk Time
This programming sequence sets the maximum time allowed for conversation when the entry system places a call to the resident. The talk time can be set from 1 second up to 255 seconds (4 minutes, 15 seconds) and is entered as a
Factory setting for talk time = 60 seconds.
1.Press and enter the four digit MASTER CODE BBBB(beep).
2.Enter three digits for talk time (seconds)
3.Press TOGETHER to end this programming step (beeeeeep).
3.1.5 Tone Open Numbers
These steps will program the tone open numbers for relays 1 and 2. You will need to enter a four- digit number (see chart below) to set the relay functions. If a function is not desired, enter # in place of a number. For example, if you want the relay to have a momentary activation function only, and you want the relay to activate when the number 9 is pressed, enter in step 3. Do not duplicate tone open numbers, i.e., don’t set relay 1, and 2
Factory setting is: Relay 1 = 9876, Relay 2 = 5432.
1.Press and enter the
2.Press to set relay 1 or to set relay 2 tone numbers.
3.Enter the
4.Repeat steps 2 and 3 to set the other relay tone open numbers.
5.Press TOGETHER to end this programming step (beeeeeep).
DIGIT | FUNCTION |
1Momentary activation. Relay will activate for the programmed strike time (3.1.3).
2Relay hold. Relay will activate and remain activated until commanded to release.
3Relay release. Deactivates the relay hold command.
4Relay hold