Friedrich SH14, SH20 installation manual Typical Installation Sill Plate, Slope down

Page 12

The illustrations below show a standard frame construction installation as well as some suggested ways of adapting the support bracket to thick walls and large stone ledges.

TYPICAL INSTALLATION SILL PLATE

Figure 1

Figure 2

 

10 - 24 Screw

 

 

10 - 24 Flat Nut

 

3/8" (10 mm)

3/8" (10 mm)

 

 

Slope down

Slope down

 

 

 

Cut

 

 

Here

 

 

 

Stone ledge

#12A x 2" Sheet metal screw

 

Outside wall

1" x 2" or 2" x 4" spacer between wall

 

Cut to fit Dimension "A" and

Discard shaded area

bend down to for a vertical leg

and bracket should be used on

 

aluminum, asbestos or vinyl siding

 

 

Figure 3

Figure 4

 

Stone ledge

Stone ledge

3/8" (10 mm)

 

3/8" (10 mm) Slope down

Slope down

 

 

#12A x 2" Sheet metal

 

Straighten tab to lay flat along

 

the bottom rail of the shell.

screw

 

Secure the longest side of the

 

 

bracket to the shell.

2" x 4" Spacer

 

Adjust in or out to rest on the ledge

 

 

 

 

 

STEP 4. CUTWINGBOARD PANELS: Measure and cut the wingboard panels from the supplied masonite (Item #8) to fit the spaces between the side window channels and the sides of the cabinet (See Figure F).

NOTE: AFTER CUTTING PANELS, MAKE A TRIAL TEST TO SEE IF THEY FIT THE SPACE WITH ABOUT 1/8" CLEARANCE BEFORE GOING TO STEP 5.

FIGURE F

Measure distance "B" to the inside of the channel on each side

Cut here and discard the center waste material

Wingboard

Subtract 1/8" (3 mm) from dimension "B" and measure from the edge of the wingboard (Item # 8), mark and cut with a saw.

Page 12

Image 12
Contents USE, CARE, Installation Manual Table of Contents Page Part 3 Maintenance Checklist Part 2 Filter InformationHazardgard Unit Special Features Part 4 Hazardgard Special FeaturesPart 5 Control Panel Function Control Power Temperature ControlPart 6 Exclusive Installation Instructions Section I Electrical RequirementsHazardgard Window Mount Installation Hardware Accessory DetailChassis Wiring and Preparation SectionUnpacking the Unit Shell Cabinet Preparation BeforeSection V Shell Installation Sash Window InstallationsTypical Installation Sill Plate Slope downSection a a Section B BTHROUGH-THE-WALL Installations Wall PreparationFigure L Frame Wall Construction Figure O Typical Installation Chassis Installation Figure PFigure Q Friedrich Hazardgard Room AIR Conditioners Limited Warranty Page Manual DE USO Instalación Y Mantenimiento Instrucciones Para USO Y Mantenimiento Instrucciones Para LA InstalacionParte SeccionPage Parte 2 Informacion Sobre EL Filtro Parte 3 Lista DE Control Para EL MantenimientoParte 4 Caracteristicas Especiales DEL Hazardgard Parte 5 Panel DE Control Parte 6 ¡EXCLUSIVAInstrucciones Para Instalacion Seccion 1 Requerimientos ElectricosLista DE Accesorios Número Descripción Cantidad De itemSeccion Desempaque DE LA UnidadPreparacion Y Instalacion Electrica DEL Chasis Preparacion DEL Armazon Gabinete AntesSeccion V Instalacion DEL Armazon Instalaciones EN Ventanas DE BastidorInstalacion Tipica DEL Filo DEL Antepecho PasoFigura G Seccion V Instalacion DE LA Armazon Instalaciones a Traves DE LA ParedConstruccion Para Paredes MAS Gruesas Requisitos DE Tamaño DE LOS HuecosFigura L Construccion EN EL Marco DE LA Pared Construccion EN Paredes DE LadrilloFigura O Instalacion Tipica Instalacion DEL Chasis De la cubierta en la caja de empalme de conexiónFigura Q Friedrich AIR Conditioning CO. INC Page Manuel ’UTILISATION Instructions D’INSTALLATION Instructions D’UTILISATION ET D’ENTRETIENChapitre GarantieNettoyer le filtre fréquemment consulter lentretien général Chapitre 2 Renseignements SUR LE Filtre Chapitre 3 DépannagePage Commande DE Température Chapitre 6 ExclusivitéInstructions D’INSTALLATION Section I Alimentation ÉlectriqueDétail DES Accessoires Référence N Déballage DE L’APPAREIL Branchement DU Châssis ET PréparationPréparation DE L’ENVELOPPE Avanta P R È SSection V Installation DE L’ENVELOPPE Installation Dans UNE Fenêtre À GuillotineInstallation Typique DE LA Plaque DE Seuil Coupe a a Section V Installation DE Lenveloppe Installation À Travers UN MURDimensions Finies DE L’OUVERTURE Figure L Construction Avec UN Cadre EN Bois Figure O Installation Typique Installation DU Châssis ÉtapeDétail Garantie Limite DUN AN Climatiseurs Hazardgard Friedrich
Related manuals
Manual 56 pages 18.6 Kb

SH14, SH20 specifications

The Friedrich SH15 and SH20 models are exemplary representatives of advanced heating solutions, designed to address the diverse needs in residential and commercial environments. Engineered with a focus on efficiency, performance, and user-friendliness, these heating systems make a strong case for modern heating technology.

One of the standout features of both the SH15 and SH20 is their energy efficiency. These models utilize state-of-the-art heat pump technology, which allows them to extract heat from the environment even in colder temperatures. This results in significantly lower energy consumption compared to traditional heating systems, leading to reduced utility bills and a lower carbon footprint. The SH15 is designed for smaller spaces, while the SH20 offers a bit more power, making it suitable for larger areas or homes with greater heating demands.

Both models incorporate advanced inverter technology, which adjusts the compressor speed depending on the heating requirements. This ensures that the units operate at optimal efficiency, providing consistent temperature control while minimizing energy waste. Inverter-driven systems contribute to quieter operation as well, which is ideal for residential settings where noise can be a concern.

User-friendliness is another hallmark of the Friedrich SH15 and SH20. Equipped with intuitive digital controls, users can easily set their preferred temperatures and schedules, allowing for personalized comfort. Moreover, both models support smart home integration, enabling remote access and control through mobile applications. This feature not only enhances convenience but also allows users to monitor energy usage and make adjustments on the fly.

Durability is a key characteristic of these heating systems. Constructed with high-quality materials, the SH15 and SH20 are designed to withstand harsh environmental conditions, ensuring long-lasting performance. They also feature advanced air filtration systems that improve indoor air quality by effectively removing allergens and other pollutants.

In summary, the Friedrich SH15 and SH20 embody the cutting-edge of heating technology, offering powerful, efficient, and user-friendly solutions for diverse heating needs. With their advanced features, smart technology integration, and robust construction, these models are well-suited for modern living, ensuring comfortable and environmentally responsible heating year-round.