Friedrich SH20, SH14 installation manual Section a a, Section B B

Page 13

FIGURE G

"J" type

speed nut (item #9)

2 required

 

 

Cut wingboard panel

Center the hole in the speed nut over the slot in the wingboard panel

Spring steel clip (item #10)

2required

Cut edge

Slide clip over cut edge of wingboard panel.

STEP 5. ASSEMBLE CLIPS TO WINGBOARD PANELS: Assemble "J" type speed nuts (Item #9) and spring steel clips (Item #10) to the edges of the cut wingboard panels (See Figure G).

FIGURE H

Secure the side wingboard panels to the side angles with four (4) #8 x 1/2" long screws (Item #11), two on each side.

Top of cabinet

Place wingboard panel in window jam to compress the springs inside the runners, and swing the panel into place indicated by the dotted line.

Window jam

SECTION A - A

STEP 6. INSTALL SIDE WINGBOARD PANELS: Be sure that the cabinet has been secured to the window sill and the outside support brackets have been installed as shown in Figures D and E on Page 11. Raise the window sash and install the right and left side wingboard panels (See Figure H).

STEP 7. INSTALL WINDOW SEALING GASKETS: Measure and cut the vinyl window seal gasket (grey color, Item #12) to fit the width of the window and install as shown in Figure I. Pull the window sash down behind the gasket. Measure and cut the dark foam window seal gasket (Item #13) and install it between the upper glass panel and the top part of the lower sash (See Figure I).

FIGURE I

Vinyl window seal gasket Item #12)

Foam window seal gasket (Item # 13)

Lower window sash

Vinyl window seal gasket

Top wingboard angle

SECTION B - B

NOTE: FOR REASONS OF SECURITY AND SAFETY, THE CUSTOMER MUST PROVIDE A MEANS OF PREVENTING THE WINDOW FROM OPENING.

STEP 8. When possible, caulk the outside of the installation with industrial type caulking to prevent air and water leaks.

Page 13

Image 13
Contents USE, CARE, Installation Manual Table of Contents Page Part 2 Filter Information Part 3 Maintenance ChecklistPart 4 Hazardgard Special Features Hazardgard Unit Special FeaturesTemperature Control Part 5 Control Panel Function Control PowerPart 6 Exclusive Section I Electrical Requirements Installation InstructionsAccessory Detail Hazardgard Window Mount Installation HardwareSection Chassis Wiring and PreparationUnpacking the Unit Before Shell Cabinet PreparationSash Window Installations Section V Shell InstallationSlope down Typical Installation Sill PlateSection B B Section a aWall Preparation THROUGH-THE-WALL InstallationsFigure L Frame Wall Construction Figure O Typical Installation Figure P Chassis InstallationFigure Q Friedrich Hazardgard Room AIR Conditioners Limited Warranty Page Manual DE USO Instalación Y Mantenimiento Instrucciones Para LA Instalacion Instrucciones Para USO Y MantenimientoParte SeccionPage Parte 3 Lista DE Control Para EL Mantenimiento Parte 2 Informacion Sobre EL FiltroParte 4 Caracteristicas Especiales DEL Hazardgard Parte 6 ¡EXCLUSIVA Parte 5 Panel DE ControlSeccion 1 Requerimientos Electricos Instrucciones Para InstalacionNúmero Descripción Cantidad De item Lista DE AccesoriosDesempaque DE LA Unidad SeccionPreparacion Y Instalacion Electrica DEL Chasis Antes Preparacion DEL Armazon GabineteInstalaciones EN Ventanas DE Bastidor Seccion V Instalacion DEL ArmazonPaso Instalacion Tipica DEL Filo DEL AntepechoFigura G Instalaciones a Traves DE LA Pared Seccion V Instalacion DE LA ArmazonConstruccion Para Paredes MAS Gruesas Requisitos DE Tamaño DE LOS HuecosConstruccion EN Paredes DE Ladrillo Figura L Construccion EN EL Marco DE LA ParedFigura O Instalacion Tipica De la cubierta en la caja de empalme de conexión Instalacion DEL ChasisFigura Q Friedrich AIR Conditioning CO. INC Page Manuel ’UTILISATION Instructions D’UTILISATION ET D’ENTRETIEN Instructions D’INSTALLATIONChapitre GarantieNettoyer le filtre fréquemment consulter lentretien général Chapitre 3 Dépannage Chapitre 2 Renseignements SUR LE FiltrePage Chapitre 6 Exclusivité Commande DE TempératureSection I Alimentation Électrique Instructions D’INSTALLATIONDétail DES Accessoires Référence N Branchement DU Châssis ET Préparation Déballage DE L’APPAREILAvanta P R È S Préparation DE L’ENVELOPPEInstallation Dans UNE Fenêtre À Guillotine Section V Installation DE L’ENVELOPPEInstallation Typique DE LA Plaque DE Seuil Coupe a a Installation À Travers UN MUR Section V Installation DE LenveloppeDimensions Finies DE L’OUVERTURE Figure L Construction Avec UN Cadre EN Bois Figure O Installation Typique Étape Installation DU ChâssisDétail Garantie Limite DUN AN Climatiseurs Hazardgard Friedrich
Related manuals
Manual 56 pages 18.6 Kb

SH14, SH20 specifications

The Friedrich SH15 and SH20 models are exemplary representatives of advanced heating solutions, designed to address the diverse needs in residential and commercial environments. Engineered with a focus on efficiency, performance, and user-friendliness, these heating systems make a strong case for modern heating technology.

One of the standout features of both the SH15 and SH20 is their energy efficiency. These models utilize state-of-the-art heat pump technology, which allows them to extract heat from the environment even in colder temperatures. This results in significantly lower energy consumption compared to traditional heating systems, leading to reduced utility bills and a lower carbon footprint. The SH15 is designed for smaller spaces, while the SH20 offers a bit more power, making it suitable for larger areas or homes with greater heating demands.

Both models incorporate advanced inverter technology, which adjusts the compressor speed depending on the heating requirements. This ensures that the units operate at optimal efficiency, providing consistent temperature control while minimizing energy waste. Inverter-driven systems contribute to quieter operation as well, which is ideal for residential settings where noise can be a concern.

User-friendliness is another hallmark of the Friedrich SH15 and SH20. Equipped with intuitive digital controls, users can easily set their preferred temperatures and schedules, allowing for personalized comfort. Moreover, both models support smart home integration, enabling remote access and control through mobile applications. This feature not only enhances convenience but also allows users to monitor energy usage and make adjustments on the fly.

Durability is a key characteristic of these heating systems. Constructed with high-quality materials, the SH15 and SH20 are designed to withstand harsh environmental conditions, ensuring long-lasting performance. They also feature advanced air filtration systems that improve indoor air quality by effectively removing allergens and other pollutants.

In summary, the Friedrich SH15 and SH20 embody the cutting-edge of heating technology, offering powerful, efficient, and user-friendly solutions for diverse heating needs. With their advanced features, smart technology integration, and robust construction, these models are well-suited for modern living, ensuring comfortable and environmentally responsible heating year-round.