TROUBLESHOOTING AND REPAIR | |||||
|
|
|
| ||
|
|
| |||
Observe Safety Guidelines detailed in the beginning of this manual. |
|
| |||
|
|
|
|
|
|
| PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED |
|
| (SYMPTOMS) |
| MISADJUSTMENT(S) | COURSE OF ACTION |
|
|
|
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
No AC welding output. DC welding | 1. | Make sure the Polarity Switch is | 1. Check the operation of the | ||
output and auxiliary power is nor- |
| in the proper position and is | Polarity Switch (S2). Also check | ||
mal. |
|
| “seated” correctly. | the associated wires for loose or | |
|
| 2. | Make sure the electrode is cor- | faulty connections. See Wiring | |
|
| Diagram. |
| ||
|
|
| rect for the process being used. |
| |
|
|
| 2. Check for continuity from lead | ||
|
| 3. Make sure the welding cables are | |||
|
|
| not coiled or too long. | “S2” to lead “E” located in the | |
|
|
| main stator. See Wiring Dia - | ||
|
|
|
| ||
|
|
|
| gram. |
|
|
|
|
| ||
No constant voltage (CV) welding | 1. | Make sure the Range Switch | 1. Check the operation of the | ||
output. Constant current (CC) and |
| (S1) is in the proper position (CV) | Range Switch (S1) and check | ||
the auxiliary power are operating |
| and “seated” correctly. | the associated wires for loose or | ||
normally. |
| 2. Make sure the wire feeder is con- | faulty connections. See Wiring | ||
|
| Diagram. |
| ||
|
|
| nected correctly. |
| |
|
|
|
|
| |
|
|
|
| 2. Check for continuity from lead | |
|
|
|
| C1 to lead W1 located in the | |
|
|
|
| main stator. See Wiring Dia- | |
|
|
|
| gram. |
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call