TROUBLESHOOTING AND REPAIR | ||
| ||
|
|
|
TYPICAL AC WELD OUTPUT WAVEFORM
MACHINE LOADED
CH1
0 volts
20 volts | 5 ms |
MACHINE LOADED TO 225 AMPS AT 25 VDC
This is the typical AC output voltage generated from a properly operating machine. Note that each vertical divi- sion represents 20 volts and that each horizontal division represents 5 mil- liseconds in time. The machine was loaded with a resistance grid bank.
Note: Scope probes connected at machine 115VAC receptacle.
SCOPE SETTINGS
Volts/Div | 20V/Div. |
Horizontal Sweep | 5 ms/Div. |
Coupling | DC |
Trigger | Internal |
|
|