Lincoln Electric SVM207-A service manual Retest After Repair

Page 90

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-52

TROUBLESHOOTING AND REPAIR

F-52

 

 

 

 

RETEST AFTER REPAIR

Retest a machine:

If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the machine’s electrical characteristics.

OR

• If you repair or replace any electrical components.

ENGINE OUTPUT

Mode

No Load RPM

Load RPM

Low Idle

2200-2400

NA

High Idle

3700-3750

3100-3750

 

 

 

WELDER DC OUTPUT1

Output Control

Range Switch

Open Circuit

Load Volts

Load Amps

 

 

Volts

 

 

Maximum

Maximum

65 - 72

21 - 26.5

205 - 240

 

 

 

 

 

WELDER AC OUTPUT1

Output Control

Range Switch

Open Circuit

Load Volts

Load Amps

 

 

Volts

 

 

Maximum

Maximum

73 - 80

25 - 32

225 - 275

 

 

 

 

 

WELDER CV OUTPUT1

Output Control

Range Switch

Open Circuit

Load Volts

Load Amps

 

 

Volts

 

 

Maximum

Wire Feed CV

29 - 33

19 - 23

200 - 220

 

 

 

 

 

AUXILIARY POWER RECEPTACLE OUTPUT1

 

230 Volt Receptacle

 

 

115 Volt Receptacle2

 

Open Circuit

Load Volts

 

Load Amps

Open Circuit

 

Load Volts

 

Load Amps

Voltage

 

 

 

Voltage

 

 

 

 

246 - 264

216 - 250

 

34 - 41.5

123- 132

 

115 - 130

 

17.5 - 21

 

 

 

 

 

 

 

 

 

 

FIELD AMPS AND VOLTS

 

 

 

Slip Ring Volts

 

Field Amps

32.0 - 45.0 VDC

 

6.5 - 7.5 VDC

 

 

 

1OUTPUT CONTROL set at MAXIMUM (position 10).

2Output values of each receptacle can vary within the range shown but must be within 2 volts of each other.

RANGER® 3 PHASE

Image 90
Contents Ranger 3 Phase Safety Ranger 3 PhaseFumes and Gases Welding Cutting Précautions DE Sûreté Safety Methods of Reducing Emissions Mains Supply Master Table of Contents for ALL Sections Table of Contents Installation Section Auxiliary Power InstallationTechnical Specifications Ranger 3 Phase K2337-1 & K2337-2 Height Width Depth WeightSpark Arrester Safety PrecautionsMachine Grounding TowingVehicle Mounting PRE-OPERATION ServiceGasoline Can cause fire or explosionHigh Altitude Operation Welding Output CablesTotal Combined Length of Electrode and Work Cables Angle of OperationInstructions Gfci Duplex Receptacles Auxiliary PowerVolt 3 Phase Receptacle with Ground 120/240 Volt Dual Voltage ReceptacleAuxiliary Power While Welding Ground WireStandby Power Connections TABLE A.1 Simultaneous Welding and PowerConnection of Ranger 3 Phase to Premises Wiring Figure A.3Electrical Device USE with the Ranger 3 Phase USE These Devices with a Ranger 3 PhaseDevices Without Addi Tional Resistive Type Loads Table of Contents Operation Section GENERAL DESCRIPTION Engine SwitchOperation Welder Controls Function and OperationRange Switch Polarity SwitchRanger 3 Phase Approximate Fuel Consumption Control DialStick Constant Current Welding Wire Feed Welding Processes Constant VoltageWelding Process TIG Constant Current WeldingStick Auto Starting the Engine STARTING/SHUTDOWN InstructionsBREAK-IN Period Stopping the EngineTable of Contents Accessories Section Accessories K1745-1 Welding GAS Cylinder LPG Tank HolderStick WIRE FEEDRECOMMENDED EQUIPMENT TIGRanger 3 Phase Table of Contents Maintenance Section Maintenance Safety PrecautionsOIL Filter Change Gfci Receptacle Testing and RESET- Ting ProcedureAIR Cleaner and Other Maintenance Slip Rings Do not attempt to polish slip rings while engine is runningFram CA79 BatteryEngine Maintenance Parts KOHLER C23S CHAMPION RC12YCMAINTENANCED-5 Figure D.1 Major Component LocationRanger 3 Phase 1TABLE of CONTENTS-THEORY of Operation Section E-1 Theory of Operation General DescriptionEngine Components and Operation ROTOR, Stator & Control Circuits Figure E.2 ROTOR, Stator and Control CircuitsWeld Circuitry Figure E.2 Weld Circuitry1TABLE of Contents Troubleshooting and Repair F-1 Troubleshooting and Repair HOW to USE Troubleshooting GuidePC Board Troubleshooting Procedures Return to SectionDiagram Perform the Output Bridge Test Gram Wiring Wiring Diagram Troubleshooting and Repair Figure F.4 and/or the Wiring Rotor Voltage Test Procedure Test DescriptionMaterials Needed Test Procedure Rotor Voltage TestRotor Resistance Test TEST PROCEDURE Figure F.2 Slip RingsAuxiliary and Field Winding Test Auxiliary Windings To test the 480 VAC 3 Phase windingProbes Reading To test the 120 VAC windingFigure F.4 Control PC Board Field WindingRanger 3 Phase Output Rectifier Bridge Test Figure F.5 OUTPUT RECTIFIER + Meter Lead Meter ReadingToroid Test Toroid Test Charging Circuit Test Voltage Regulator AC Lead DC Lead Engine Throttle Adjustment Test Engine Throttle Adjustment Test Low Idle Adjustment SolenoidNut Housing Figure F.9 115VAC Supply Waveform High IDLE- no Load Scope Settings Normal Open Circuit Voltage Waveform 115 VAC SupplyHigh Idle no Load Output Control AT Maximum Typical DC Weld Output Waveform CV Mode Machine LoadedTypical DC Weld Output Waveform CC Mode Machine Loaded to 200 Amps AT 26 VDCTypical AC Weld Output Waveform Machine Loaded to 225 Amps AT 25 VDCAbnormal Open Circuit Weld Voltage Waveform CV Mode Abnormal Open Circuit DC Weld Voltage Waveform Normal Open Circuit Weld Voltage Waveform CV Mode Normal Open Circuit DC Weld Voltage Waveform CC Mode Normal Open Circuit AC Weld Voltage Waveform Ranger 3 Phase Brush Removal and Replacement Procedure Brush Removal and Replacement Procedure ProcedureBrush Assembly Bracket Bolts Ranger 3 Phase Printed Circuit Board Removal Replacement Procedure Printed Circuit Board Removal Figure F.10 Door RemovalOutput Rectifier Bridge Removal Replacement Procedure Output Rectifier Bridge Removal Figure F.11 OUTPUT RECTIFIERENGINE/ROTOR Removal and Replacement Procedure ENGINE/ROTOR Removal and Replacement Procedure Procedure Rotor Removal Procedure Figure F.13 Engine and Rotor Removed from StatorReassembly Procedure Retest After Repair Table of Contents Diagram Section Ranger 3-PHASE RaNGEr 3 phaSESchEmaTic cOmplETE machiNE l12259 L12259ElEcTrical DiaGramS