RETEST AFTER REPAIR
Retest a machine :
•If it is rejected under test for any reason that requires you to remove any part which could affect the machine’s electrical charac- teristics.
OR
•If you repair or replace any electrical components.
SET UP
1.Connect a supply of filtered compressed air at 80 psi to the gas inlet.
2.Supply 15 to 110 VAC to the machine.
3.Connect the gun to the connector block and connect the trigger.
| OPERATION VERIFICATION | |
WIRE FEED SPEED (Standard) | 50 through 700 IPM | |
WIRE FEED SPEED (Ext. Torque) | 50 through 400 IPM | |
VOLTMETER (Analog) | ..............Must read Inpit Voltage | |
VOLTMETER (Digital) | Must operate at 3 TO 12 VDC input volts | |
GAS SOLENOID | Must operate when Gun Trigger is activated. | |
CONTACTOR | Must operate when Gun Trigger is activated | |
| or after |