TROUBLESHOOTING & REPAIR | ||||||
TROUBLESHOOTING GUIDE |
|
| Observe Safety Guidelines | |||
|
|
| detailed in the beginning of this manual. | |||
|
|
|
|
|
|
|
PROBLEMS |
|
| POSSIBLE AREAS OF |
| RECOMMENDED |
|
(SYMPTOMS) |
|
| MISADJUSTMENT(S) |
| COURSE OF ACTION |
|
|
|
|
|
|
|
|
|
|
| TIG MODE PROBLEMS |
|
|
|
Machine output is intermittently lost. | 1. | The problem may be caused by | 1. | Check for loose or faulty connec- | ||
Gas flow and high frequency are |
| high frequency interference. |
| tion on the leads between the |
| |
also interrupted. |
|
| Make sure that the machine is |
| remote receptacle and plug J5 |
|
|
|
| grounded properly according to |
| on the control board. See wiring | |
|
|
| the installation instructions. If |
| diagram. |
|
|
|
| there are other high frequency |
|
|
|
|
|
| sources in the area, make certain | 2. Check the plugs on the control | ||
|
|
| that they are grounded properly. |
| board for loose connections. |
|
|
| 2. | Make sure the Amptrol is operat- | 3. | The control board may be faulty. | |
|
|
| ing properly. |
|
|
|
|
| 3. Check to make sure that the |
|
|
| |
|
|
| input voltage is correct for the |
|
|
|
|
|
| machine reconnect configuration. |
|
|
|
|
|
| Refer to Reconnect Procedure |
|
|
|
|
|
| in the Installation section of this |
|
|
|
|
|
| manual. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|