Lincoln Electric SVM169-A High Voltage Transformer, Transformer Secondary Leads Precision TIG

Page 88

Section TOC

Master TOC

F-50

TROUBLESHOOTING & REPAIR

F-50

HIGH VOLTAGE TRANSFORMER

REMOVAL AND REPLACEMENT PROCEDURE (Continued)

Return to

Return to Master TOC

REMOVAL PROCEDURE

1.Remove input power to the TIG 185 machine.

2.Using the 3/8” nutdriver remove the case wrap-around cover.

3.With the needle nose pliers remove the two secondary leads from the quick-con- nects on the high frequency arc starter board assembly. See Figure F.11.

4.Disconnect the in-line splice quick con- nect from one primary lead to lead #231A. Cut any necessary cable ties.

5.Remove the lead splice from the other pri- mary lead that is connected to lead #236 and the C4 capacitor. See wiring dia- gram. Cut any necessary cable ties.

6.Using the phillips head screwdriver remove the front mounting screws from the base of the high voltage transformer. Take note of insulator placement for reassembly. NOTE: On some machines the mounting screw configuration may be different.

7.With phillips head screwdriver loosen the two rear mounting screws.

8.Carefully slide the transformer forward and remove from the TIG 185 machine.

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

FIGURE F.11 SECONDARY LEADS AT HIGH FREQUENCY STARTER BOARD

TRANSFORMER

SECONDARY

LEADS

PRECISION TIG 185

Image 88
Contents Precision TIG Safety Electric Shock can kill Safety Welding Sparks can cause fire or explosionPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcMaster Table of Contents for ALL Sections Table of Contents Installation SectionInstallation Input Single Phase onlyModel Height Width Depth Weight K2345-2 Input at Rated OutputSafety Precautions Select Suitable LocationInput Connections Input Reconnect Procedure Output ConnectionsConnections for TIG Gtaw Welding TIG Torch ConnectionWork Cable Connection Remote Control ConnectionShielding GAS Connection Precision TIG Operation Section Section BOperation Product Description Recommended Processes and EquipmentControls and Settings Control FunctionalityOperating Steps Welding in TIG ModePulse TIG Control Remote Control Operation Benefits of the Precision TIG 185 DesignWelding in Stick Mode Recommended Electrode Amperage Ranges Precision TIGPrecision TIG Accessories Section Factory Installed Options AccessoriesTable C.1 Field Installed Options K2348-1 Under-Storage CartPrecision TIG Maintenance Section Section DRoutine and Periodic Maintenance MaintenanceSpark GAP Adjustment Figure D.2 Location of Maintenance Components Return to Section TOC Theory of Operation Section Section ETheory of Operation Input Power CircuitGeneral Description Output Rectification Feedback Control Figure E.3 Control Board and Output Feedback ControlHigh Voltage / High Frequency Circuit Figure E.4 High Voltage/High Frequency CircuitDC Welding Output Figure E.5 DC Welding Current GenerationAC Welding Output Figure E.6 AC Square Wave Welding Current GenerationSCR Operation Figure E.7 SCR OperationThermal Protection Protective CircuitsOverload Protection Troubleshooting & Repair Section Section FTroubleshooting & Repair High Voltage / High Frequency can damage test equipmentPC Board Troubleshooting Procedures WorkstationsProblems Possible Areas Recommended Symptoms Course of ActionPossible Areas Recommended Symptoms Problems Possible Areas Check the welding cables and or TIG Mode Problems Troubleshooting & Repair TIG Welding Problems Problems Possible Areas Electric Shock can Problems Possible Areas Recommended Symptoms Stick Welding Problems High Frequency Circuit Disable Procedure Test DescriptionProcedure Figure F.1 Spark GAP AssemblyT1 Transformer Test Test Procedure T1 Transformer TestReturn to Section Section TOC Primary Windings Primary VoltagesPrecision TIG Static SCR Test Static SCR Test Assembly Removal and Replacement Precision TIG Active SCR Test Active SCR Test Figure F.6 SCR Gate Locations Precision TIG Scope Settings AC TIG ModeNormal Open Circuit Voltage Waveform DC TIG Mode AC Stick Mode DC Stick Mode Typical Output Voltage Waveform Machine Loaded Machine Loaded to 180 Amps AT 16VDCDC TIG Mode Machine Loaded to 180 Amps AT 26VDC DC Stick Mode 50 V/Div Precision TIG Troubleshooting and Repair SCR Bridge Assembly Removal and Replacement ProcedureSCR Bridge Assembly ProcedureFront Panel Mounting Screws 42TROUBLESHOOTING & REPAIRF-42 Figure F.9 Plug J2 on Control Board43TROUBLESHOOTING & REPAIRF-43 Replacement ProcedurePrecision TIG Polarity Switch Removal and Replacement Procedure Polarity Switch Removal ProcedureReplacement Procedure Precision TIG High Voltage Transformer Removal and Replacement Procedure High Voltage Transformer Transformer Secondary Leads Precision TIGFigure F.12 High Voltage Transformer Mounting Insulators Precision TIG Nutdriver Wrench Wire cutters Perform the SCR Bridge Assembly Removal Procedure Assembly Replacement Procedure Precision TIG Troubleshooting and Repair Retest After RepairInput Idle Amps Recommended Meters for Machine Output TestsPrecision TIG Electrical Diagrams Section Wiring Diagram Entire Machine G4549 Precision TIGSchematic Entire Machine G4588 G4588Schematic Control PC Board G4550-1B4-1 Schematic Control P.C. Board G4550-1B4-2 Schematic Control P.C. Board G4550-1B4-3 PC Board Assembly Control G4551-1 G4551SVM Error Reporting Form