TROUBLESHOOTING & REPAIR | ||||||
TROUBLESHOOTING GUIDE |
|
| Observe Safety Guidelines | |||
|
|
| detailed in the beginning of this manual. | |||
|
|
|
|
|
|
|
| PROBLEMS |
| POSSIBLE AREAS OF |
| RECOMMENDED |
|
| (SYMPTOMS) |
| MISADJUSTMENT(S) |
| COURSE OF ACTION |
|
|
|
|
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
|
Machine welds at a very low output 1. | If welding in the TIG mode the | 1. | Check the polarity switch and |
| ||
regardless of the current control set- | remote control device may be |
| associated leads. |
| ||
ting. |
|
| defective. |
|
|
|
|
|
|
| 2. | Check the interior connections of | |
| 2. | Make certain the input line volt- |
| the heavy current carrying leads. | ||
|
|
| age is correct for the machine |
|
|
|
|
|
| reconnect configuration. | 3. | Perform the SCR Bridge Test. | |
| 3. | Check the welding cables and or | 4. | Perform the T1 Transformer |
| |
|
|
| torch for loose or faulty connec- |
| Test. |
|
|
|
| tions. |
|
|
|
|
|
|
| 5. | Check the current control for |
|
|
|
|
|
| proper operation. Normal resis- | |
|
|
|
|
| tance is 10k ohms. See wiring |
|
|
|
|
|
| diagram. |
|
|
|
|
| 6. The control board may be faulty. |
The machine welds at a very high | 1. If welding in the TIG mode the | 1. | Perform the SCR Bridge Test. |
output regardless of the current con- | remote control device may be |
|
|
trol setting. | defective. | 2. | Perform the T1 Transformer |
|
|
| Test. |
|
| 3. | Check the current control for |
|
|
| proper operation. Normal resis- |
|
|
| tance is 10k ohms. See wiring |
|
|
| diagram. |
|
| 4. | The control board may be faulty. |