TROUBLESHOOTING & REPAIR |
ABNORMAL OPEN CIRCUIT VOLTAGE - DC TIG MODE
ONE OUTPUT SCR NOT FUNCTIONING
CAUTION
HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.
•Perform all voltage and waveform checks with high frequency circuit OFF.
•Perform High Frequency Disable Procedure.
____________________________________________________________________
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
50 V
This is NOT the typical DC (+) output voltage waveform. One output SCR is not function- ing. Note the “gap”in the waveform. One SCR gate was disconnected to simulate an open or
Note: Scope probes connected at machine
output terminals: (+) probe to electrode,
0 V
2 ms
SCOPE SETTINGS
Volts/Div | 50 V/Div. |
Horizontal Sweep | 2 ms/Div. |
Coupling | DC |
Trigger | Internal |
|
|