| TROUBLESHOOTING & REPAIR |
|
|
| ||
| TROUBLESHOOTING GUIDE |
| Observe Safety Guidelines | |||
|
| detailed in the beginning of this manual. | ||||
|
|
|
|
|
| |
| PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
|
| |
| (SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION |
|
| |
|
|
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
|
|
| The engine starts and runs at the | 1. Check the AC auxiliary output | 1. Check for loose or faulty con- | |||
| correct speed, but there is no AC | circuit breakers. Reset is nec- | nections between the recepta- | |||
| auxiliary output voltage. The DC | essary. | cles, the circuit breakers, the | |||
| welding generator is functioning | 2. Check the 115VAC and 230VAC | current | transformer and | the | |
| correctly. | exciter alternator stator. | See | |||
| receptacles and plugs for loose | |||||
|
| the Wiring Diagram. |
|
| ||
|
| or faulty connections. |
|
| ||
|
|
|
|
|
| |
|
|
| 2. Check | the 115VAC | and | |
|
|
| 230VAC windings in the alterna- | |||
|
|
| tor stator for shorted turns or | |||
|
|
| grounds. | Check the continuity | ||
|
|
| of the windings. See the Wiring | |||
|
|
| Diagram. |
|
|
The engine starts and runs normal- | 1. Contact your local Authorized | 1. Check the “flashing” diode |
ly. The machine takes a long time | Field Service Facility. | located on the DC generator |
to |
| brush holder. The diode may |
voltage. The AC auxiliary voltage |
| be “shorted” or installed incor- |
varies when the Fine Current |
| rectly. |
Control rheostat is adjusted. |
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-