Lincoln Electric SVM104-A service manual

Page 1

SVM104-A

March, 1999

PRO-CUT60 (Single Phase)

For use with machines having Code Numbers: 9819, 10096, 10112 10118, 10217, 10218 10393, 10394

Safety Depends on You

Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thoughtful operation on your part. DO NOT

INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS

CONTAINED THROUGHOUT. And, most importantly, think before you act and be careful.

ON

OFF

o

1

SERVICE MANUAL

World's Leader in Welding and Cutting Products

 

Premier Manufacturer of Industrial Motors

• Sales and Service through Subsidiaries and Distributors Worldwide •

Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100

FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com

Image 1
Contents SVM104-A Electric Shock can kill SafetyWelding or Cutting Sparks can cause fire or explosion Electric and Magnetic Fields IiiSûreté Pour Soudage a L’Arc Précautions DE SûretéMaster Table of Contents for ALL Sections Table of Contents Technical Specifications PRO-CUT InstallationSelect Proper Location Safety Precautions Electric Shock can KillHigh Frequency Interference Protection TiltingInput Electrical Connections ➁ ➂ ➀ ➃Input Power Supply Connections Fuse and Wire SizesGround Connection AIR Input Connections 208/230/460 VAC machines Reconnect ProcedureWork Output ConnectionsOperation Section Table of ContentsElectric Shock can kill OperationDesign Features Advantages Operational Features and ControlsGeneral Description Recommended Processes and EquipmentCutting and Gouging Capability Controls and SettingsLimitations ON/OFF Operating StepsUse Pilot Arc Properly Cutting Procedure RecommendationsCutting Thin Gauge Sheet Metal Cutting Expanded Metal Figure B.3 -- Gouging Metal Return to Section TOC Accessories Section OPTIONS/ACCESSORIES AccessoriesSection D Maintenance SectionSafety Precautions MaintenanceCapacitor Discharge Procedure Procedure DescriptionFigure D.1 Capacitor Discharge Procedure ProcedurePerform the following daily Routine and Periodic MaintenanceMaintenance PRO-CUT Theory of Operation Section Theory of Operation SectionInput Line Voltage and Main Transformer Theory of OperationFigure E.3 Output Rectification, Control and Feedback Output Rectification Control and FeedbackHigh Voltage / High Pilot ARC Theory of OperationFigure E.7 Transistor Switching Operation Transistor Switching OperationThermal Protection Pulse Width ModulationThermostat Thermal SensorPRO-CUT Troubleshooting & Repair Section HOW to USE Troubleshooting Guide Troubleshooting & RepairBoard can be dam- aged by static electricity Troubleshooting PC Board Troubleshooting ProceduresTroubleshooting Guide PRO-CUT Troubleshooting GuideConnect ALL Input Disconnect ALL Input Machine Troubleshooting & Repair Function Problems AIR Flow Problems Cutting Problems Power Board Connector Location Control Board Connector LocationCapacitor Discharge Procedure Insulated Pliers Gloves Figure F.19-Capacitor Discharge ProcedureTest Description Work Torch and Cable Resistance Test ProcedureFigure F.4 Torch and Cable Resistance Test Points Internal Trigger Safety Circuit TestReturn to Return to Section TOC Figure F.6-Control Board and 4-pin Locations Test Description Transistor Module TestTest Procedure J21 Main Transformer Test Test a Main Secondary Voltage Test Test ProcedureCR2 Power Board Test Figure F.11-Power Board Test Points Transistor Module Test Troubleshooting & Repair High Voltage Transformer and Circuit Test Figure F.12-High Voltage Test Component Locations Test C Test Resistance of High Voltage Transformer Secondary REMOVAL/REPLACEMENT Description ON/OFF Power Switch Removal➂ ➃ ➄ REMOVAL/REPLACEMENT ProcedureControl Board Removal To Section TOC Power Board Removal Figure F.14-Power Board Removal/Replacement Return to Return to Section TOC Transistor Module Removal 41TROUBLESHOOTING & RepairRemoval Procedure SCR Module Removal Socket Head CAP Screws Torque to Power Board REMOVAL/ Replacement Procedure FAN Blade and FAN Motor REMOVAL/REPLACEMENT Figure F.17-Fan Blade & Fan Motor To Section TOC Torch Head REMOVAL/REPLACEMENT Figure F.18-Torch Head Removal/Replacement Section TOC Retest After Repair Maximum Acceptable Output Voltage AT Minimum Output SettingInput Idle Amps Recommended Meters for Machine Output TestsPRO-CUT Electrical Diagrams Electrical DiagramsStatus Board Schematic Diagram H E M a T I C Bypass Board Schematic Diagram M15603Bypass Board Schematic Diagram M17322 PRO-CUT Electrical Diagrams Identification Control BoardPower Board Identification Power BoardM15601 Status Status PC BoardM15601 Status PC BoardBypass Bypass PC Board M15603Bypass PC Board M15603 Bypass PC Board M17322 Bypass PC Board M17322 0 , J 2 Wiring Diagram for Codes 10112Wiring Diagram for Codes 9819 Control Board Schematic Drawing G2015 Power Board Schematic Design SVM Error Reporting Form