NOTE: See Figure F.19.

1.Disconnect input power to the machine.

2.Remove the Left Case Side Assembly.

3.Locate the two capacitors shown in Figure F.19.

4.Put on the insulated gloves.

5.Grip the middle of the resistor with the insulated pliers.

6.Touch the resistor leads across the two capacitor straps as shown for 10 seconds.

a.DO NOT TOUCH THE CAPACITOR STRAPS WITH YOUR HANDS OR ANY OTHER PART OF YOUR BODY.

7.Test for zero volts across the capacitor terminals with a DC volt meter.

a.Capacitor terminal polarity is marked on the capacitor straps.

b.If any voltage is measured,

REPEAT PROCEDURE.

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

INSULATED

PLIERS

INSULATED

GLOVES

FIGURE F.19-Capacitor Discharge Procedure

PRO-CUT 60

Image 55
Contents SVM104-A Electric Shock can kill SafetyWelding or Cutting Sparks can cause fire or explosion Electric and Magnetic Fields IiiSûreté Pour Soudage a L’Arc Précautions DE SûretéMaster Table of Contents for ALL Sections Table of Contents Technical Specifications PRO-CUT InstallationTilting Safety Precautions Electric Shock can KillSelect Proper Location High Frequency Interference ProtectionInput Electrical Connections ➁ ➂ ➀ ➃Input Power Supply Connections Fuse and Wire SizesGround Connection AIR Input Connections 208/230/460 VAC machines Reconnect ProcedureWork Output ConnectionsOperation Section Table of ContentsElectric Shock can kill OperationRecommended Processes and Equipment Operational Features and ControlsDesign Features Advantages General DescriptionCutting and Gouging Capability Controls and SettingsLimitations ON/OFF Operating StepsUse Pilot Arc Properly Cutting Procedure RecommendationsCutting Thin Gauge Sheet Metal Cutting Expanded Metal Figure B.3 -- Gouging Metal Return to Section TOC Accessories Section OPTIONS/ACCESSORIES AccessoriesSection D Maintenance SectionProcedure Description MaintenanceSafety Precautions Capacitor Discharge ProcedureFigure D.1 Capacitor Discharge Procedure ProcedurePerform the following daily Routine and Periodic MaintenanceMaintenance PRO-CUT Theory of Operation Section Theory of Operation SectionInput Line Voltage and Main Transformer Theory of OperationFigure E.3 Output Rectification, Control and Feedback Output Rectification Control and FeedbackHigh Voltage / High Pilot ARC Theory of OperationFigure E.7 Transistor Switching Operation Transistor Switching OperationThermal Sensor Pulse Width ModulationThermal Protection ThermostatPRO-CUT Troubleshooting & Repair Section HOW to USE Troubleshooting Guide Troubleshooting & RepairBoard can be dam- aged by static electricity Troubleshooting PC Board Troubleshooting ProceduresTroubleshooting Guide PRO-CUT Troubleshooting GuideConnect ALL Input Disconnect ALL Input Machine Troubleshooting & Repair Function Problems AIR Flow Problems Cutting Problems Power Board Connector Location Control Board Connector LocationCapacitor Discharge Procedure Insulated Pliers Gloves Figure F.19-Capacitor Discharge ProcedureTest Description Work Torch and Cable Resistance Test ProcedureFigure F.4 Torch and Cable Resistance Test Points Internal Trigger Safety Circuit TestReturn to Return to Section TOC Figure F.6-Control Board and 4-pin Locations Test Description Transistor Module TestTest Procedure J21 Main Transformer Test Test a Main Secondary Voltage Test Test ProcedureCR2 Power Board Test Figure F.11-Power Board Test Points Transistor Module Test Troubleshooting & Repair High Voltage Transformer and Circuit Test Figure F.12-High Voltage Test Component Locations Test C Test Resistance of High Voltage Transformer Secondary REMOVAL/REPLACEMENT Description ON/OFF Power Switch Removal➂ ➃ ➄ REMOVAL/REPLACEMENT ProcedureControl Board Removal To Section TOC Power Board Removal Figure F.14-Power Board Removal/Replacement Return to Return to Section TOC Transistor Module Removal 41TROUBLESHOOTING & RepairRemoval Procedure SCR Module Removal Socket Head CAP Screws Torque to Power Board REMOVAL/ Replacement Procedure FAN Blade and FAN Motor REMOVAL/REPLACEMENT Figure F.17-Fan Blade & Fan Motor To Section TOC Torch Head REMOVAL/REPLACEMENT Figure F.18-Torch Head Removal/Replacement Section TOC Recommended Meters for Machine Output Tests Maximum Acceptable Output Voltage AT Minimum Output SettingRetest After Repair Input Idle AmpsPRO-CUT Electrical Diagrams Electrical DiagramsStatus Board Schematic Diagram H E M a T I C Bypass Board Schematic Diagram M15603Bypass Board Schematic Diagram M17322 PRO-CUT Electrical Diagrams Identification Control BoardPower Board Identification Power BoardM15601 Status Status PC BoardM15601 Status PC BoardBypass Bypass PC Board M15603Bypass PC Board M15603 Bypass PC Board M17322 Bypass PC Board M17322 0 , J 2 Wiring Diagram for Codes 10112Wiring Diagram for Codes 9819 Control Board Schematic Drawing G2015 Power Board Schematic Design SVM Error Reporting Form