Lincoln Electric SVM104-A service manual Figure F.17-Fan Blade & Fan Motor

Page 88

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-47

TROUBLESHOOTING & REPAIR

FAN BLADE AND FAN MOTOR REMOVAL/REPLACEMENT

FAN

BRACKET

MOTOR

FIGURE F.17-Fan Blade & Fan Motor

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

REMOVAL/REPLACEMENT PROCEDURE

NOTE: See Figure F.17.

1.Disconnect input power to the machine.

2.Perform the CAPACITOR DISCHARGE PROCEDURE.

3.Disconnect the air line to the air regulator on the Case Back Assembly.

4.Remove the Case Back Assembly Access Door.

5.Disconnect the input power supply leads from the terminal block.

6.Remove the six screws from the Case Back Assembly. There are two screws at the top and four at the bottom. After the last screw is removed, be prepared to use a strap or other support to keep the Case Back Assembly from falling open. The motor leads could be pulled out of their con- nectors if this should happen.

7.Unscrew the brass air line con- nector from the male elbow using pliers or channel locks.

8.Remove the brass air line con- nector and companion nylon compression fitting.

PRO-CUT 60

Image 88
Contents SVM104-A Safety Electric Shock can killWelding or Cutting Sparks can cause fire or explosion Iii Electric and Magnetic FieldsPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcMaster Table of Contents for ALL Sections Table of Contents Installation Technical Specifications PRO-CUTSafety Precautions Electric Shock can Kill Select Proper LocationHigh Frequency Interference Protection Tilting➁ ➂ ➀ ➃ Input Electrical ConnectionsInput Power Supply Connections Fuse and Wire SizesGround Connection AIR Input Connections Reconnect Procedure 208/230/460 VAC machinesOutput Connections WorkTable of Contents Operation SectionOperation Electric Shock can killOperational Features and Controls Design Features AdvantagesGeneral Description Recommended Processes and EquipmentCutting and Gouging Capability Controls and SettingsLimitations Operating Steps ON/OFFCutting Procedure Recommendations Use Pilot Arc ProperlyCutting Thin Gauge Sheet Metal Cutting Expanded Metal Figure B.3 -- Gouging Metal Return to Section TOC Accessories Section Accessories OPTIONS/ACCESSORIESMaintenance Section Section DMaintenance Safety PrecautionsCapacitor Discharge Procedure Procedure DescriptionProcedure Figure D.1 Capacitor Discharge ProcedureRoutine and Periodic Maintenance Perform the following dailyMaintenance PRO-CUT Theory of Operation Section Theory of Operation SectionTheory of Operation Input Line Voltage and Main TransformerOutput Rectification Control and Feedback Figure E.3 Output Rectification, Control and FeedbackHigh Voltage / High Theory of Operation Pilot ARCTransistor Switching Operation Figure E.7 Transistor Switching OperationPulse Width Modulation Thermal ProtectionThermostat Thermal SensorPRO-CUT Troubleshooting & Repair Section Troubleshooting & Repair HOW to USE Troubleshooting GuideTroubleshooting PC Board Troubleshooting Procedures Board can be dam- aged by static electricityTroubleshooting Guide Troubleshooting Guide PRO-CUTConnect ALL Input Disconnect ALL Input Machine Troubleshooting & Repair Function Problems AIR Flow Problems Cutting Problems Control Board Connector Location Power Board Connector LocationCapacitor Discharge Procedure Figure F.19-Capacitor Discharge Procedure Insulated Pliers GlovesTest Description Torch and Cable Resistance Test Procedure WorkFigure F.4 Torch and Cable Resistance Test Points Safety Circuit Test Internal TriggerReturn to Return to Section TOC Figure F.6-Control Board and 4-pin Locations Transistor Module Test Test DescriptionTest Procedure J21 Main Transformer Test Test Procedure Test a Main Secondary Voltage TestCR2 Power Board Test Figure F.11-Power Board Test Points Transistor Module Test Troubleshooting & Repair High Voltage Transformer and Circuit Test Figure F.12-High Voltage Test Component Locations Test C Test Resistance of High Voltage Transformer Secondary ON/OFF Power Switch Removal REMOVAL/REPLACEMENT DescriptionREMOVAL/REPLACEMENT Procedure ➂ ➃ ➄Control Board Removal To Section TOC Power Board Removal Figure F.14-Power Board Removal/Replacement Return to Return to Section TOC 41TROUBLESHOOTING & Repair Transistor Module RemovalRemoval Procedure SCR Module Removal Socket Head CAP Screws Torque to Power Board REMOVAL/ Replacement Procedure FAN Blade and FAN Motor REMOVAL/REPLACEMENT Figure F.17-Fan Blade & Fan Motor To Section TOC Torch Head REMOVAL/REPLACEMENT Figure F.18-Torch Head Removal/Replacement Section TOC Maximum Acceptable Output Voltage AT Minimum Output Setting Retest After RepairInput Idle Amps Recommended Meters for Machine Output TestsPRO-CUT Electrical Diagrams Electrical DiagramsStatus Board Schematic Diagram Bypass Board Schematic Diagram M15603 H E M a T I CBypass Board Schematic Diagram M17322 PRO-CUT Electrical Diagrams Control Board IdentificationPower Board Power Board IdentificationStatus PC Board M15601 StatusStatus PC Board M15601Bypass PC Board M15603 BypassBypass PC Board M15603 Bypass PC Board M17322 Bypass PC Board M17322 Wiring Diagram for Codes 10112 0 , J 2Wiring Diagram for Codes 9819 Control Board Schematic Drawing G2015 Power Board Schematic Design SVM Error Reporting Form