TROUBLESHOOTING & REPAIR |
RETEST AFTER REPAIR
Should a machine under test be rejected for any reason requiring the removal of any mechanical part that could affect the machine’s electrical characteristics, or if any electrical components are repaired or replaced, the machine must be retested.
INPUT IDLE AMPS
INPUT VOLTS / HERTZ | MAXIMUM IDLE AMPS |
|
|
208 / 60 | 4.4 |
|
|
230 / 60 | 4.0 |
|
|
460 / 60 | 2.0 |
575 / 60 | 1.6 |
|
|
MAXIMUM ACCEPTABLE OUTPUT VOLTAGE -
AT MINIMUM OUTPUT SETTING
Output Control at Minimum | 26 Amps @ 43VDC |
|
|
MINIMUM ACCEPTABLE OUTPUT VOLTAGE -
AT MAXIMUM OUTPUT SETTINGS
Output Control at Maximum | 60 Amps @ 90VDC |
|
|
RECOMMENDED METERS FOR MACHINE OUTPUT TESTS
VOLTMETER: | Analog type meter |