Lincoln Electric SVM104-A service manual Function Problems

Page 50

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-9

TROUBLESHOOTING & REPAIR

 

 

 

TROUBLESHOOTING GUIDE

 

Observe Safety Guidelines

 

 

 

detailed in the beginning of this manual.

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

 

Airflow does not shut off.

1. Remove input power to the

1. Remove leads #38 and

 

 

PRO-CUT 60. If the air con-

#31 (plug J12) from air

 

 

tinues to flow the air solenoid

solenoid (SV1).

Refer to

 

 

(SV1) could be jammed or

wiring diagram.

 

 

 

 

stuck open.

a. If air continues to flow

 

 

2. If air pressure is above

the solenoid is faulty.

 

 

 

Replace.

 

 

 

 

125 PSI solenoid may be

b. If the airflow stops when

 

 

damaged. Set for 60-65 PSI.

the

solenoid (SV1) leads

 

 

 

are

removed

then

the

 

 

 

Control Board

could

be

 

 

 

faulty.

 

 

 

 

 

The "OUTPUT ON" and "AIR

Turn power off - then restart

1. The Control Board could

PRESSURE" LED's

blink in

machine

be faulty. Replace.

 

alternating order.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed call 216-383-2531 or 1-800-833-9353.

PRO-CUT 60

Image 50
Contents SVM104-A Safety Electric Shock can killWelding or Cutting Sparks can cause fire or explosion Iii Electric and Magnetic FieldsPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcMaster Table of Contents for ALL Sections Table of Contents Installation Technical Specifications PRO-CUTHigh Frequency Interference Protection Safety Precautions Electric Shock can KillSelect Proper Location Tilting➁ ➂ ➀ ➃ Input Electrical ConnectionsGround Connection Fuse and Wire SizesInput Power Supply Connections AIR Input Connections Reconnect Procedure 208/230/460 VAC machinesOutput Connections WorkTable of Contents Operation SectionOperation Electric Shock can killGeneral Description Operational Features and ControlsDesign Features Advantages Recommended Processes and EquipmentLimitations Controls and SettingsCutting and Gouging Capability Operating Steps ON/OFFCutting Procedure Recommendations Use Pilot Arc ProperlyCutting Thin Gauge Sheet Metal Cutting Expanded Metal Figure B.3 -- Gouging Metal Return to Section TOC Accessories Section Accessories OPTIONS/ACCESSORIESMaintenance Section Section DCapacitor Discharge Procedure MaintenanceSafety Precautions Procedure DescriptionProcedure Figure D.1 Capacitor Discharge ProcedureRoutine and Periodic Maintenance Perform the following dailyMaintenance PRO-CUT Theory of Operation Section Theory of Operation SectionTheory of Operation Input Line Voltage and Main TransformerOutput Rectification Control and Feedback Figure E.3 Output Rectification, Control and FeedbackHigh Voltage / High Theory of Operation Pilot ARCTransistor Switching Operation Figure E.7 Transistor Switching OperationThermostat Pulse Width ModulationThermal Protection Thermal SensorPRO-CUT Troubleshooting & Repair Section Troubleshooting & Repair HOW to USE Troubleshooting GuideTroubleshooting PC Board Troubleshooting Procedures Board can be dam- aged by static electricityTroubleshooting Guide Troubleshooting Guide PRO-CUTConnect ALL Input Disconnect ALL Input Machine Troubleshooting & Repair Function Problems AIR Flow Problems Cutting Problems Control Board Connector Location Power Board Connector LocationCapacitor Discharge Procedure Figure F.19-Capacitor Discharge Procedure Insulated Pliers GlovesTest Description Torch and Cable Resistance Test Procedure WorkFigure F.4 Torch and Cable Resistance Test Points Safety Circuit Test Internal TriggerReturn to Return to Section TOC Figure F.6-Control Board and 4-pin Locations Transistor Module Test Test DescriptionTest Procedure J21 Main Transformer Test Test Procedure Test a Main Secondary Voltage TestCR2 Power Board Test Figure F.11-Power Board Test Points Transistor Module Test Troubleshooting & Repair High Voltage Transformer and Circuit Test Figure F.12-High Voltage Test Component Locations Test C Test Resistance of High Voltage Transformer Secondary ON/OFF Power Switch Removal REMOVAL/REPLACEMENT DescriptionREMOVAL/REPLACEMENT Procedure ➂ ➃ ➄Control Board Removal To Section TOC Power Board Removal Figure F.14-Power Board Removal/Replacement Return to Return to Section TOC 41TROUBLESHOOTING & Repair Transistor Module RemovalRemoval Procedure SCR Module Removal Socket Head CAP Screws Torque to Power Board REMOVAL/ Replacement Procedure FAN Blade and FAN Motor REMOVAL/REPLACEMENT Figure F.17-Fan Blade & Fan Motor To Section TOC Torch Head REMOVAL/REPLACEMENT Figure F.18-Torch Head Removal/Replacement Section TOC Input Idle Amps Maximum Acceptable Output Voltage AT Minimum Output SettingRetest After Repair Recommended Meters for Machine Output TestsPRO-CUT Electrical Diagrams Electrical DiagramsStatus Board Schematic Diagram Bypass Board Schematic Diagram M15603 H E M a T I CBypass Board Schematic Diagram M17322 PRO-CUT Electrical Diagrams Control Board IdentificationPower Board Power Board IdentificationStatus PC Board M15601 StatusStatus PC Board M15601Bypass PC Board M15603 BypassBypass PC Board M15603 Bypass PC Board M17322 Bypass PC Board M17322 Wiring Diagram for Codes 10112 0 , J 2Wiring Diagram for Codes 9819 Control Board Schematic Drawing G2015 Power Board Schematic Design SVM Error Reporting Form