TROUBLESHOOTING & REPAIR | ||||||
|
|
|
| |||
TROUBLESHOOTING GUIDE |
|
| Observe Safety Guidelines | |||
|
|
| detailed in the beginning of this manual. | |||
|
|
|
|
|
| |
| PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED |
| |
| (SYMPTOMS) |
| MISADJUSTMENT(S) | COURSE OF ACTION |
| |
|
|
|
|
|
|
|
|
|
| FEEDING PROBLEMS |
|
|
|
Meter reads low voltage | Local/Remote Switch must be in | 1. | See Output Diodes test. |
| ||
and output is extremely low or no | LOCAL position unless Remote |
|
|
| ||
output. |
| Control device is attached to remote | 2. | See Capacitor Balance | tests. | |
|
|
| receptacle. |
|
|
|
|
|
|
| 3. | See Switch Board test. |
|
|
|
|
| 4. | See Power Board test. |
|
|
|
|
| 5. | Control Board may be defective. |
Poor welding, weld settings drift, or | Check welding procedures and weld | 1. | Check Mode Switch S2 for dam- | ||
output power is low. | cable connections. |
| age and continuity. |
| |
| Check with machine on local con- |
|
|
|
|
| trol. | 2. | Check | for continuity | between |
|
|
| Mode Switch S2 and Control | ||
| Check input voltages and input volt- |
| Board. See Wiring Diagram in | ||
| age reconnect procedures. See |
| Section G. |
| |
| Installation section of this manual. |
|
|
|
|
|
| 3. | Check for loose or faulty con- | ||
|
|
| nections in heavy | ||
|
|
| ing leads (i.e., choke, shunt, | ||
|
|
| output | bridge, and | output |
|
|
| studs). See wiring diagram in | ||
|
|
| Section G. |
|
4. See Overcurrent Protection Current Trigger Circuit tests.
5. See Control Board test
Welding “too hot”. Actual weld cur- | Check condition of the shunt and | See Step 7 of the Overcurrent |
rent is considerably higher than dis- | leads to the Control Board. | Protection Current Trigger test |
play indicates. |
| If shunt and leads check OK, possi- |
|
| |
|
| ble defective Control Board |
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call