TROUBLESHOOTING & REPAIR |
PROTECTION BOARD OUTPUT TEST(cont.)
FIGURE F.6 - INSERTING PROBES
Return
Return to Section TOC
TOC
Return
Return to Master TOC
TOC
306
275F
L7915
313
J8 |
PROTECTION
J15
Return to Section
Return to Section TOC
Return to Master
Return to Master TOC
311
TEST PROCEDURE
12.Open S4 and Turn Power OFF
13.Move probes to test between leads 306 (+) and 275
14.Turn Power ON and close S4. If voltage is less than 1 VDC, Protection Board is OK. If voltage is greater than 14 VDC, Protection Board may be defective.See Overvoltage Protection DC Trigger Circuit test, Step 11.