TROUBLESHOOTING & REPAIR |
ADDITIONAL INFORMATION
OSCILLOSCOPE WARNING
Do not use oscilloscopes and other pieces of test equipment that are powered by 115 VAC. This equipment should not be used with
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
INPUT FILTER CAPACITOR CONDITION- ING
Capacitor conditioning may be required if the machine will not produce output after power is applied and the following two conditions exist::
The machine is connected to a supply of 380 v.a.c. or higher
and
Power has not been applied to the machine for an extended period of time (months).
To condition the input filter capacitors:
1.Turn the Power Switch OFF
2.Remove any load and do not load the machine until the capacitor conditioning is completed.
3.Turn the Power Switch ON and leave the machine energized for at least 30 minutes.
4.Cycle the Power Switch OFF and on again .
The machine should now work normally. If not,contin- ue with the Troubleshooting Section of this manual.
MATCHED PARTS
The following parts must be replaced in matched sets:
Output Diodes D1, D2, D3, D4, and D5.
Output Diodes D7, D8, D9, D10, and D11.
Note: On newer codes where Diode Modules are used in place of individual diodes, both modules on a heat sink assembly should be replaced if one fails.
Capacitor Bleeder Resistors: R1 & R9
Capacitors: C1 & C2
Capacitors C1, C2, C14 & C15 on 575 v.a.c. units.
Switch Boards proir to